-
E-mail
info@z-dream.cn
-
Phone
19916533110
-
Address
Building 1, No. 139 Xuanqiu Road, Pudong New Area, Shanghai
Shanghai Zimeng Technology Co., Ltd
info@z-dream.cn
19916533110
Building 1, No. 139 Xuanqiu Road, Pudong New Area, Shanghai
Beckman Coulter Laboratory Liquid Particle Counter
Liquid particle counter|Advantages of choosing HIAC 9703+
The industry's smallest sample
Only 1mL of the product can complete the full set of tests
Manage all your application requirements
According to the pre configured USP, EP, JP, and KP testing routines, the full range of sample volumes can be processed, ranging from 1 milliliter to over 1000 milliliters
Eliminate uncertainty based on data anomalies
When bubbles or sensors are contaminated and may affect particle counting results, an alarm notification will be issued
The handling of samples is safe and reliable
Using a small bottle holder to ensure that expensive samples are not wasted
Easy to configure for maximum flexibility
Choose a flow rate of * and use interchangeable sensors to detect particle sizes ranging from 0.5 to 600 μ m
Avoid high cost downtime
On site service can effectively reduce downtime - there is no need to transport your instrument, and it will automatically notify you when your instrument needs routine maintenance
Eliminated your concerns about data loss
The recovery function for lost data can protect test data in the event of an unexpected power outage. PharmSpec allows operators to schedule the time for backing up the database to a secure network site.
Verification service for HIAC particle counter
SOP assistance and IQ verification services apply our professional skills to make your system ready for use once it is removed from the packaging box.
| Part Number | description |
| 90450001 | Small bottle sampling needle, 0.063 "O.D.X 5.88" long, stainless steel |
| 90620008 | Small bottle sampling probe, 0.25 "x 5.88" long, stainless steel |
| 90630002 | Nut, used to secure the small bottle sampling probe to the sensor |
| 089208-01 | Exhaust pipe component |
| 230-300-7052 | Power supply,+24 VDC @ 3A |
| VP623500 | Universal European power cord, AC, 6 feet long, 230V |
| VP623501 | Universal US power cord, AC, 6 feet long, 115V |
| 460-400-4799 | USB cable 2.0 Pro series, high-speed |
| 600-100-0003 | Magnetic stirring rod, coated with PTFE |
| 690-300-4808 | Syringe, 10ml, XLP type |
| 808-010-200 | 2-010 Fluororubber O-ring, used for sensor accessories, two per set |
| 680-000-0030 | Hexagonal wrench, 1.5 millimeters |
| DOC026.97.80097 | 9703+User Manual |
| Part Number | description |
| 2089006-01 | The small bottle sampling tool kit includes: P/N 2089099-01, small bottle clamp assembly; P / N 90450004 , Small bottle sampling probe 0063 "x 3" long; P / N 690-300-4805 , Syringe, 1 milliliter XLP type |
| 2089099-01 | Small bottle clamp component |
| 90450004 | Small bottle sampling probe, length 0.063 "x 3" |
| 690-300-4805 | Syringe, 1 milliliter, XLP type |
| 690-300-4809 | Syringe, 25ml, XLP type |
| FACTORY_CAL_USP_PRE | Each USP has undergone USP factory calibration |
| 2089290-01 | HRLD sensor bracket assembly |
| 2089291-01 | MC-05 Sensor Bracket Assembly |
| 2089179-01 | Cable components, HRLD to 9703+ |
USP<788>/Insoluble particles in injections and injection liquids
HIAC 9703+Liquid Particle Counting System
HIAC PharmSpec Liquid Particle Counting Software
HIAC HRLD Liquid Particle Counting Sensor
HIAC MC05 Liquid Particle Counting Sensor (Submicron Scale)
Regulatory link for liquid particle counters:
USP<788>
USP<789>
USP<797>
USP<789>Insoluble particles in ophthalmic solutions:
HIAC 9703+Liquid Particle Counting System
HIAC PharmSpec Liquid Particle Counting Software
HIAC HRLD Liquid Particle Counting Sensor
HIAC MC05 Liquid Particle Counting Sensor (Submicron Scale)
USP<797>Drug Preparation - Aseptic Preparations
HIAC 9703+Liquid Particle Counting System
HIAC PharmSpec Liquid Particle Counting Software
HIAC HRLD Liquid Particle Counting Sensor
HIAC MC05 Liquid Particle Counting Sensor (Submicron Scale)
Liquid particle counting release test standard:
USP<788>Insoluble particles in injections and injectable liquids
USP<789>Insoluble particles in ophthalmic solutions
USP<7897>Drug Preparation - Aseptic Preparations
Test setup is simple and easy to use
Pressing the button will reveal the pharmacopoeial testing methods for USP, EP, JP, and KP
Customize testing methods using PharmSpec program generator
Everything is safe and the data is reliable
The database can be securely migrated from the old Windows operating system to the new Windows 7 and higher versions
Network backup and archiving can be configured
*Complies with the requirements of 21 CFR Part 11 regulations
The software is pre configured - no professional knowledge required
Authorized users are free to update USP<788>, USP<789>, EP, JP, or KP pharmacopoeias annually
There are intuitive settings for new users - invalid configurations will trigger an alarm, and calibration expiration will be notified in advance
Early detection of abnormal data
Can use bubble detection and centralized alarm sensors to stop tracking abnormal data
Can confirm all particle counting results; Partial results of incomplete testing will also be recorded
PharmSpec software/firmware update
▪ PharmSpec Update USP 38 787 (Zip) - Upgrades existing USP functionality to the current pharmacopoeia level. This update is only applicable to PharmSpec V3.3.
▪ PharmSpec Update USP 38 788 (Zip) - Upgrades existing USP functionality to the current pharmacopoeia level.
▪ PharmSpec Update USP 38 789 (Zip) - Upgrades existing USP functionality to the current pharmacopoeia level.
▪ PharmSpec Update JP XVI (Zip) - Upgrade the existing JP functionality to the current pharmacopoeia level.
▪ PharmSpec Update EP 7 (Zip) - Updates existing EP functionality to current compendial level.
▪ PharmSpec Update EP8 (Zip) - Upgrade existing EP functionality to the current pharmacopoeia level.
▪ PharmSpec Update KP 11 (Zip) - Upgrade the existing EP functionality to the current pharmacopoeia level.
▪ PharmSpec Update V3.1.4 (Zip) - PharmSpec Update V3.1.4 (Zip) - The updated PharmSpec V3.1.1, V3.1.2, and V3.1.3 information can be found in the readme. txt file. The updates on this website are only valid for PharmSpec V3.1.1, V3.1.2, and V3.1.3
▪ PharmSpec V3.1x (Zip) - Website Language Update
| weight | 10.7 kg kg |
| size | 343mm W X 337mm D X 482mm H |
| operating temperature | 5 to 40 ° C; relative humidity 0 to 80%, no condensation |
| Sample temperature | 5 to 40 ° C |
| power supply | 100/230 VAC, 50/60 Hz, 67 W at 115/230 VAC |
| Viscosity limit | <50 cp=''> |
| Gap in sampling bottle | 153 mm |
| Volume accuracy | > 95% |
| Flow velocity accuracy | > 95% |
| Sample flow rate | 10 to 100 milliliters per minute; The actual flow rate of the system is determined by the flow rate of the sensor |
| Pre extraction volume of probe | For a probe of 81 L x 1.2I. D mm, the volume is 0.091 ml, For a probe of 154 L x 1.2 mm I.D., the amount is 0.172 ml For a 140 L x 6.35 I. D mm probe, it is 1.57mL (5.5 x 0.25 inches) - large aperture |
| processor | Pentium® 1.0 GHz |
| operating system | Windows ® XP, Windows Vista with Service Pack 3 or higher ® Windows 7 with Service Pack 2 or higher (32-bit) |
| memory | 512MB RAM |
| hard disk | 2GB hard drive space |
| optical disc drive | CD drive, DVD drive, USB port or network connection, used for installing software |
| display | High quality VGA video adapter and monitor, 1024 x 768 or higher resolution |
| power supply | Continuous power supply (UPS) |
| Detachable optical drive | A detachable optical drive can back up data, such as a recordable CD or a network server, which can back up data from a computer's hard drive |
| printer | Color printer, capable of printing at a resolution of 300dpi |
| COM port | The USD port can be connected to the particle counting system |
| software | Internet Explorer 6.0 or higher and Microsoft ® Excel ®, Word ® Or Adobe ® Acrobat ® (Access PharmSpec report) |