The WQ sewage lift pump is suitable for conveying granular sewage and waste in industries such as chemical, petroleum, pharmaceutical, mining, paper industry, cement plant, steel plant, power plant, coal processing industry, as well as urban sewage treatment plant drainage system, municipal engineering, construction sites, etc. It is also used for pumping clean water and corrosive media.

| serial number | model | Caliber mm | Flow rate m3/h | Head m | Power KW | Speed r/min | Efficiency% |
| 1 | 25 WQ 8-22-1.1 | 25 | 8 | 22 | 1.1 | 2900 | 38.5 |
| 2 | 32 WQ 12-15-1.1 | 32 | 12 | 15 | 1.1 | 2900 | 40 |
| 3 | 40 WQ 15-15-1.5 | 40 | 15 | 15 | 1.5 | 2900 | 45.1 |
| 4 | 40 WQ 15-30-2.2 | 40 | 15 | 30 | 2.2 | 2900 | 48 |
| 5 | 50 WQ 20-7-0.75 | 50 | 20 | 7 | 0.75 | 2900 | 54 |
| 6 | 50 WQ 10-10-0.75 | 50 | 10 | 10 | 0.75 | 2900 | 56 |
| 7 | 50 WQ 20-15-1.5 | 50 | 20 | 15 | 1.5 | 2900 | 55 |
| 8 | 50 WQ 15-25-2.2 | 50 | 15 | 25 | 2.2 | 2900 | 56 |
| 9 | 50 WQ 25-20-2.2 | 50 | 25 | 20 | 2.2 | 2900 | 56 |
| 10 | 50 WQ 18-30-3 | 50 | 18 | 30 | 3 | 2900 | 58 |
| 11 | 50 WQ 25-32-5.5 | 50 | 25 | 32 | 5.5 | 2900 | 53 |
| 12 | 50 WQ 20-40-7.5 | 50 | 20 | 40 | 7.5 | 2900 | 55 |
| 13 | 65 WQ 25-15-2.2 | 65 | 25 | 15 | 2.2 | 2900 | 52 |
| 14 | 65 WQ 37-13-3 | 65 | 37 | 13 | 3 | 2900 | 55 |
| 15 | 65 WQ 25-30-4 | 65 | 25 | 30 | 4 | 2900 | 58 |
| 16 | 65 WQ 30-40-7.5 | 65 | 30 | 40 | 7.5 | 2900 | 56 |
| 17 | 65 WQ 35-50-11 | 65 | 35 | 50 | 11 | 2900 | 60 |
| 18 | 65 WQ 35-60-15 | 65 | 35 | 60 | 15 | 2900 | 63 |
| 19 | 80 WQ 40-7-2.2 | 80 | 40 | 7 | 2.2 | 1450 | 52 |
| 20 | 80 WQ 43-13-3 | 80 | 43 | 13 | 3 | 2900 | 50 |
| 21 | 80 WQ 40-15-4 | 80 | 40 | 15 | 4 | 2900 | 57 |
| 22 | 80 WQ 65-25-7.5 | 80 | 65 | 25 | 7.5 | 2900 | 56 |
| 23 | 100 WQ 80-10-4 | 100 | 80 | 10 | 4 | 1450 | 62 |
| 24 | 100 WQ 110-10-5.5 | 100 | 110 | 10 | 5.5 | 1450 | 66 |
| 25 | 100 WQ 100-15-7.5 | 100 | 100 | 15 | 7.5 | 1450 | 67 |
| 26 | 100 WQ 80-20-7.5 | 100 | 80 | 20 | 7.5 | 1450 | 68 |
| 27 | 100 WQ 100-25-11 | 100 | 100 | 25 | 11 | 1450 | 65 |
| 28 | 100 WQ 100-30-15 | 100 | 100 | 30 | 15 | 1450 | 66 |
| 29 | 100 WQ100-35-18.5 | 100 | 100 | 35 | 18.5 | 1450 | 65 |
| 30 | 125 WQ 100-15-11 | 125 | 100 | 15 | 11 | 1450 | 62 |
| 31 | 125 WQ 130-20-15 | 125 | 130 | 20 | 15 | 1450 | 63 |
| 32 | 150 WQ 145-9-7.5 | 150 | 145 | 9 | 7.5 | 1450 | 63 |
| 33 | 150 WQ 180-15-15 | 150 | 180 | 15 | 15 | 1450 | 65 |
| 34 | 150 WQ 180-20-18.5 | 150 | 180 | 20 | 18.5 | 1450 | 75 |
| 35 | 150 WQ 180-25-22 | 150 | 180 | 25 | 22 | 1450 | 76 |
| 36 | 150 WQ 130-30-22 | 150 | 130 | 30 | 22 | 1450 | 75 |
| 37 | 150 WQ 180-30-30 | 150 | 180 | 30 | 30 | 1450 | 73 |
| 38 | 150 WQ 200-30-37 | 150 | 200 | 30 | 37 | 1450 | 70 |
| 39 | 150 WQ 160-45-37 | 150 | 160 | 37 | 37 | 1450 | 70 |
| 40 | 200 WQ 300-7-11 | 200 | 300 | 7 | 11 | 980 | 73 |
| 41 | 200 WQ 250-11-15 | 200 | 250 | 11 | 15 | 980 | 74 |
| 42 | 200 WQ 250-15-18.5 | 200 | 250 | 15 | 18.5 | 1450 | 72 |
| 43 | 200 WQ 400-10-22 | 200 | 400 | 10 | 22 | 1450 | 76 |
| 44 | 200 WQ 400-13-30 | 200 | 400 | 13 | 30 | 1450 | 73 |
| 45 | 200 WQ 300-15-22 | 200 | 300 | 15 | 22 | 1450 | 73 |
| 46 | 200 WQ 250-22-30 | 200 | 250 | 22 | 30 | 1450 | 71 |
| 47 | 200 WQ 350-25-37 | 200 | 350 | 25 | 37 | 1450 | 75 |
| 48 | 200 WQ 400-30-55 | 200 | 400 | 30 | 55 | 1450 | 70 |
| 49 | 250 WQ 600-9-30 | 250 | 600 | 9 | 30 | 980 | 74 |
| 50 | 250 WQ 600-12-37 | 250 | 600 | 12 | 37 | 1450 | 78 |
| 51 | 250 WQ 600-15-55 | 250 | 600 | 15 | 55 | 1450 | 75 |
| 52 | 250 WQ 600-20-55 | 250 | 600 | 20 | 55 | 1450 | 73 |
| 53 | 300 WQ 500-15-45 | 300 | 500 | 15 | 45 | 980 | 70 |
| 54 | 300 WQ 800-15-55 | 300 | 800 | 15 | 55 | 980 | 73 |
| 55 | 300 WQ 600-20-55 | 300 | 600 | 20 | 55 | 980 | 75 |
| 56 | 300 WQ 800-20-75 | 300 | 800 | 20 | 75 | 980 | 78 |
| 57 | 300 WQ 950-20-90 | 300 | 950 | 20 | 90 | 980 | 80 |
| 58 | 300 WQ 1000-25-110 | 300 | 1000 | 25 | 110 | 980 | 82 |
| 59 | 350 WQ 1100-10-55 | 350 | 1100 | 10 | 55 | 980 | 84.5 |
| 60 | 350 WQ 1500-15-90 | 350 | 1500 | 15 | 90 | 980 | 82.5 |
| 61 | 350 WQ 1200-18-90 | 350 | 1200 | 18 | 90 | 980 | 83.1 |
| 62 | 350 WQ 1100-28-132 | 350 | 1100 | 28 | 132 | 740 | 83.2 |
| 63 | 350 WQ 1000-36-160 | 350 | 1000 | 36 | 160 | 740 | 78.5 |
| 64 | 400 WQ 2000-15-132 | 400 | 2000 | 15 | 132 | 740 | 85.5 |
| 65 | 400 WQ 1700-22-160 | 400 | 1700 | 22 | 160 | 740 | 82.1 |
| 66 | 400 WQ 1500-26-160 | 400 | 1500 | 26 | 160 | 740 | 83.5 |
| 67 | 400 WQ 1700-30-200 | 400 | 1700 | 30 | 200 | 740 | 83.5 |
| 68 | 400 WQ 1800-32-250 | 400 | 1800 | 32 | 250 | 740 | 82.1 |
| 69 | 500 WQ 2500-10-110 | 500 | 2500 | 10 | 110 | 740 | 82 |
| 70 | 500 WQ 2600-15-160 | 500 | 2600 | 15 | 160 | 740 | 83 |
| 71 | 500 WQ 2400-22-220 | 500 | 2400 | 22 | 220 | 740 | 84 |
| 72 | 500 WQ 2600-24-250 | 500 | 2600 | 24 | 250 | 740 | 82 |
The QW and WQ non clogging submersible sewage pumps consist of two parts: the motor, which are separated by an oil isolation chamber and mechanical seal components. They are integrated products of the motor, and the motor and pump share the same shaft (rotor). The entire length of the water pump is short and the structure is compact. Equipped with multiple protective devices to ensure safe and reliable operation of the pump. The main components are as follows: signal line 1: equipped with a fully protected water pump control cabinet, providing comprehensive protection for the pump, including water leakage, phase failure, short circuit, overheating, motor overload, and other items.
Motor stator 8: adopts B-level or F-level insulation.
Leakage probe 11: This component is installed in the oil chamber. When the mechanical seal is damaged and water enters the oil chamber, the probe can send a signal to the control system to protect the pump.
Mechanical Seal 13: Adopting dual channel punch seal and using new hard and corrosion-resistant tungsten carbide material, it has the characteristics of reliable sealing, wear resistance, and long service life.
Impeller 17: The impeller adopts a single or double channel structure, which has strong passing capacity and can pass large materials and fiber waste, reducing blockage and entanglement failures.
Pump body 15: Paired with the impeller, the pump has high efficiency.
Sealing ring 18: installed at the mouth ring of the pump body. When the impeller wears out the mouth ring due to operation, the sealing ring can be replaced to ensure optimal efficiency of the pump operation.








| Fault phenomenon | Cause analysis | Exclusion method |
| Insufficient flow or no water output | 1. Impeller rotation error 2. Is the valve open and intact 3. The pipeline is blocked 4. Low speed 5. Head too high 6. The density of the pumping medium is relatively high 7. High viscosity of the medium 8. Damaged sealing ring (at the mouth ring) |
1. Adjust the rotation direction of the impeller 2. Check, repair, and eliminate 3. Clean up debris 4. Check electrical equipment and circuits 5. Change the pump or reduce the head 6. Dilute with water to reduce concentration 7. Reduce viscosity 8. Replace |
| Unstable operation | 1. Unbalanced impeller 2. Bearing damage |
1. Send to the manufacturer for replacement or calibration 2. Replace the impeller |
| The pump cannot start | 1. Lack of phase 2. Impeller stuck 3. Winding, connector or cable open circuit 4. Stator winding burnt out 5. Electrical control malfunction |
1. Check the circuit for repair 2. Remove debris 3. Use an ohmmeter to check and repair 4. Repair and replace the winding 5. Repair or replace |
| excessive current | 1. Low working voltage 2. Pipeline and impeller blockage 3. Transporting liquids that have passed or have high viscosity 4. Using a lift that is too high |
1. Adjust the working voltage 2. Clean the pipeline and replace the winding 3. Change density or viscosity 4. Reduce traffic and increase traffic |
| Low insulation resistance | 1. Leakage at the power supply terminal of the cable 2. Cable damage 3. Mechanical seal wear leads to leakage 4. Failure of each O-ring seal 5. The casing is corroded by the medium and leaks water |
1. Tighten the compression nut 2. Replace 3. Replace 4. Replace 5. Repair |