Characteristics of Oklon Variable Frequency Chiller
1. Variable frequency energy-saving
The energy-saving of frequency converters is mainly manifested in the application of fans and water pumps. In order to ensure the reliability of production, various production machinery are designed with a certain amount of surplus when equipped with power drives. When the motor cannot operate at full load, in addition to meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in the waste of electrical energy. The traditional speed regulation method for equipment such as fans and pumps is to adjust the air and water supply volume by adjusting the opening of the inlet or outlet baffles and valves. The input power is high, and a large amount of energy is consumed in the interception process of the baffles and valves. When using variable frequency speed regulation, if the flow rate requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
2. Power factor compensation for energy saving
Reactive power not only increases line loss and equipment heating, but more importantly, the decrease in power factor leads to a reduction in active power in the power grid. A large amount of reactive energy is consumed in the lines, resulting in low equipment efficiency and serious waste. After using a variable frequency speed regulation device, the effect of the internal filtering capacitor of the frequency converter reduces reactive power loss and increases the active power of the power grid.
3. Soft start energy-saving
Hard starting of motors causes serious impact on the power grid, and also demands excessive capacity from the grid. The high current and vibration generated during starting can cause significant damage to baffles and valves, which is extremely detrimental to the service life of equipment and pipelines. After using the frequency conversion energy-saving device, the soft start function of the frequency converter will start the starting current from zero, and the maximum value will not exceed the rated current, reducing the impact on the power grid and the requirements for power supply capacity, and extending the service life of equipment and valves. Saved equipment maintenance costs.