Triple quadrupole liquid chromatography-mass spectrometer company

NegotiableUpdate on 01/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The AB Sciex 5500 triple quadrupole liquid chromatography-mass spectrometry instrument has a wider quantitative linear dynamic range, quantitative analysis sensitivity, and is suitable for quantitative analysis of low concentration components in complex matrix samples. When quantitatively analyzing small molecule compounds, it can provide data accuracy and reproducibility.

Product Details

AB Sciex 5500 Triple Quadrupole Liquid Mass Spectrometry InstrumentIt has a wider quantitative linear dynamic range, quantitative analysis sensitivity, and is suitable for quantitative analysis of low concentration components in complex matrix samples. When quantitatively analyzing small molecule compounds, it can provide data accuracy and reproducibility.


In order to achieve the high sensitivity required for DMPK and ADME research,AB Sciex 5500 Triple Quadrupole Liquid Mass Spectrometry InstrumentQJet has been configured ™- 2 ion introduction focusing device and Turbo V ™ Ion source and next-generation Analyst 1.5 ® The software forms a high-throughput analysis platform suitable for each stage of Yao's material development research, with higher quantitative performance.

AB Sciex 5500

Quality range: 5-1000 Da

Resolution:>12000 FWHM (Trap)

Sensitivity: 2400 amu/sec (3Q), 20000 amu/sec (Trap)

Polarity switching time: 50 ms


QJetTM-2 ion introduction technology: greatly improves system sensitivity and enhances vacuum distribution

Bending LINAC ® Collision chamber: improves ion transport speed, increases ion capacity, effectively prevents cross contamination, and enhances mass spectrometry data quality

Q3 linear acceleration technology: greatly improves MS/MS scanning capability

MRM-IDA-EPI (Rod Trap Scanning) method: can establish a high-quality EPI mass spectrometry library

AcQuRateTM Pulse Ion Counting Detector: Ensuring System Reproducibility and Accuracy

EQTM electronic design: ensuring fast scanning and fast positive negative switching scanning


[Scope of Application]

Provide quantitative analysis of metabolites in target metabolic pathways, such as arachidonic acid metabolism pathway, canine urea amino acid metabolism pathway, glycolysis pathway, tricarboxylic acid cycle and other key pathways.