Technical Specifications
Measurement method: Titration colorimetric method
Measurement range: Total hardness:0.21-534.0 ppm CaCO3 (see reagent type), total alkalinity: 5.34-2050 ppm CaCO3 (see reagent type)
Measurement time: approximately3 minutes, depending on the hardness/alkalinity concentration of the water
Accuracy: The upper limit of the selected reagent+/- 5%
Repeatability: The upper limit of the selected reagent+/- 2.5%
Reagent consumption: approximately0.05-0.5ml/analysis, depending on the measured concentration
Reagent expiration date: factory2 years (<25 ℃,>
Water sample consumption: Approximately consumed per analysis1L water sample (at 2 bar pressure)
power supply85-265 VAC, 47-63Hz
power waste:25VA (operating), 3.5VA (standby)
Protection level:IP65
Display: graphic backlightLCD display
Optional units:°dH、°f、ppm CaCO3、mmol/l、°e
output:1. 4 sets of programmable relay outputs (max.250V, 4A)
2. 1 set of 0/4-20 mA signal, max 750 Ω
3. RS485 Modbus RTU communication
Input1. IN1 input (start analysis/flow control switch/water meter)
2. IN2 input (reset device)
Analysis cycle: time interval measurement(5-360min)/External signal/Flow signal
Rinse time: adjustable(15~1800s)
Water quality requirements: colorless, no suspended solids, no bubbles;pH: 4 – 10 ; Iron:<3 ppm; Copper:<0.2 ppm=''>
Temperature: Environment: 5 ° C-45 ° C, water sample: 5 ° C-40 ° C
humidity20-90%RH, Indoor installation
Stress0.5-5 bar (max) (recommended 1-2 bar)
enter/Water outlet connection: 6mm outer diameter hose
size/Weight: 300 × 300 × 200mm (W × H × D), approximately 4Kg
Installation method: Wall mounted
Order Number |
description |
33-5000-00 |
PACON 5000Online hardness analyzer |
33-5000-10 |
PACON 5000Online alkalinity analyzer |
50-5000-10 |
Spare parts package, including peristaltic pump head (including pump tube), sealing ring, agitator, reagent bottle connecting tube, recommended to be replaced once a year |
50-5000-20 |
LEDLight source, it is recommended to replace it every two years |
hardness/Alkalinity reagent
TC/TH
parameter
Capacity:500ml/bottle
Validity period: Ex factory24 months
Measurement frequency:5000-10000 times
Storage: Store in a cool place and avoid direct sunlight(<25℃)<>