The DRK-G300 laser particle size analyzer (wet dry dual-use) is a versatile particle size analysis instrument. This instrument adopts a split design, that is, the injector and the host are separated. Supports both wet and dry detection dispersion methods, making mode expansion and conversion more convenient. The plug-in pipeline design can be matched with corresponding injectors and detection windows to switch detection modes. Micro, high-capacity, or corrosion-resistant injection systems can also be optionally selected.
The DRK-G300 laser particle size analyzer is based on the principle of full range Mie scattering theory, designed in accordance with ISO international technical standards. The structure adopts a pure helium neon gas light source and a large angle non-uniform cross fan-shaped ultra large detector array design, fully considering the detection angle and sensitivity, ensuring the wide range testing range of the instrument and the accuracy and repeatability of the test results.
Wet dispersion:
The DRK-G300 laser particle size analyzer ultrasonic dispersion system can fully disperse the tested sample. The high-power ultrasonic device (100W) is designed with anti dry burning protection, and the ultrasonic time is fully automatically and continuously adjusted. The ultrasonic time can be set according to the difficulty of sample dispersion. Good shielding treatment allows for simultaneous ultrasonic dispersion and sample testing, and even particles with agglomeration can be fully dispersed to obtain true particle size distribution data.
The sample dispersion pool is made of stainless steel material, which is circular in shape and easy to circulate and drain. The micro arc design does not leave dust and dirt, making it easy to clean, and it has a liquid level protection device.
Wet dispersion has automated functions such as automatic water inlet, automatic testing, automatic determination of light path status, automatic elimination of bubbles, and automatic cleaning. It can use distilled water, purified water, alcohol, and other liquids as dispersion media.
Circulating mixing system: Select the appropriate circulating mixing speed based on the characteristics of the tested sample to prevent particle precipitation in the circulation pipeline. The circulating pump speed is fully automatic and continuously adjustable, with digital display set. Simultaneously turning on ultrasound during the testing process can avoid testing errors caused by bubbles generated due to excessive circulation speed and prevent particle agglomeration during the circulation process.
Dry dispersion:
The sample is uniformly transported to the high-pressure airflow through an automatic dry powder sampler, and continuously sprayed at high speed into the disperser under the drive of the high-pressure airflow. At the outlet of the disperser, the sample has been fully dispersed, and after passing through the laser beam, it enters the collector/In the vacuum cleaner, the computer immediately displays the particle size distribution information.
1. Dry dispersion does not require any dispersants or solvents. The dispersion principle is shown in the following figure
2. Adopt oil-free air compressor and high-efficiency condenser to ensure the production of pure compressed air;
3. Instantaneous dispersion and measurement, fast testing accuracy, high analysis efficiency, and instantaneous completion of injection to output results;
4. Automatic sampling, supporting fully automatic one click operation.
5. The duckbill nozzle greatly improves the stability and accuracy of detection.
Technical Specifications:
Specification Model |
DRK-300W (wet process) DRK-300D (dry process) DRK-G300 (wet dry dual-use) |
||
test scope |
Wet method:0.01-3000um Dry process:0.1-3000um |
repeatability error |
<1% (National Standard Material D50) |
Measuring principle |
米氏散射原理 |
Accuracy error |
<1% (National Standard Material D50) |
measurement method |
Wet method: dual stage dispersion with stirring and ultrasound Dry method: duckbill nozzle Vibration and Venturi two-stage dispersion |
Optical path system |
High transparency coated lens High precision 3D automatic centering Automatic judgment and warning function for optical path |
laser light source |
Pure helium neon gas laser |
sample pool |
400ml micro arc bottom with physical level gauge, designed to prevent particle aggregation and deposition |
detector |
Sensitive large-area detection unit Three dimensional distribution of front, rear, and lateral double rows |
Operation method |
Both dry and wet methods support one click fully automatic and manual operation |
Cycle speed |
Highest achievable5000 revolutions per minute, continuously adjustable |
Ultrasonic device |
100W, Adjustable from 0-9 minutes and 50 seconds, Designed with anti dry burn protection |
interface method |
Network port andUSB dual communication |
instrument structure |
Split type, metal body, pipeline quick plug |
Application scope:
It is suitable for particle size analysis and testing in powder coatings, building materials, cement, metallurgy and chemical industry, coal minerals, pharmaceutical pesticides, health care products, ceramic abrasives, catalysts, precious metals, such as heavy calcium, light calcium, kaolin, graphite, wollastonite, brucite, barite, mica powder, bentonite, diatomite, clay, silicon dioxide, garnet, zirconium silicate, zirconia, magnesium oxide, zinc oxide, river sediment, lithium battery materials, catalysts, phosphor, cement, abrasives, medicine, pesticides, food, coatings, dyes, ceramic raw materials, chemical materials, nanomaterials, paper filler coatings, various lotion and other fields.
Based on the design principle of the versatile laser particle size analyzer, it is suitable for detecting solid powder particles, as well as mixed solutions such as suspensions and emulsions.
Analysis software:
(1) The PADMAS Particle Diameter Measure&Analysis System has powerful and rich functions, and the test data can be processed through averaging, statistics, comparison, and trend analysis. It has various formats such as differential distribution, cumulative distribution, standard grading, volume distribution, area distribution, quantity distribution, R-R distribution, custom grading, and item grading.
(Data Trends)
(2) Strong visibility: The testing software interface is user-friendly, the testing process is clear and visible, with instant refresh and strong visibility. The instrument operation status and test data fluctuation can be observed at any time, and the authenticity and reliability of the measured data can be analyzed.
(3) Objective reality: Automatic calculation by analysis software.
(4) Easy to operate: Standard, quantitative, and simple operations can be mastered proficiently in a short period of time.
For pharmaceutical industry clients, the software complies with pharmacopoeia standardsAccording to GMP regulations, it has functions such as audit tracking, electronic signature, permission setting, audit tracking, and data immutability, and can provide 3Q templates to assist with 3Q certification.
Test report:
The test report includes particle size distribution curves, detailed particle size data tables, and custom summary tablesD3、D10、D50、D90、D97、D(1,0)、D(3,2)、D(4,3)、 Characteristic parameters such as span, peak particle size, and specific surface area are available, and multiple custom parameters can be entered as needed. The weight specific surface area and volume specific surface area can be interchanged. It can save granularity distribution graphics and granularity data charts as images, and also supports PDF, WORD, and EXCEL report templates. Support printing of test reports in both Chinese and English formats, with header and footer that can be modified as needed, and print preview function.