Shanghai Leici WZS-186 turbidity meter with LED light source, meeting ISO7027 standard; Adopting the principle of scattered transmitted light measurement and automatic chromaticity compensation; Automatic range switching; Support zero point and Z-multiple 7-point calibration; Support for average measurement function, compensating for reading fluctuations caused by random floating of suspended solids in the sample through average calculation;

Product Details

Brand: Shanghai Leici (Yidian)
Name: Turbidity meter, Turbidity meter
Model: WZS-186

Shanghai Leici WZS-186 turbidity meter

【 Main Features 】

lLEDLight source, satisfyingISO7027Standard;

lUsing scattering-Transmission light measurement principle, automatic chromaticity compensation;

lAutomatic range switching;

lSupports Zero Point and Multiple 7Point calibration;

lSupport average measurement function, compensating for reading fluctuations caused by random floating of suspended solids in the sample through average calculation;

lCompliant with GLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to2000Group;

lEquipped with standard USBCommunication interface, supporting andPCconnect;

lIt has power-off protection function.

model

Technical Specifications

WZS-186

Measurement Range (NTU)

020.00NTU, (20.0200.0NTU, (2002000NTU

indication error

Not exceeding ± 6%

repetitiveness

Not exceeding 0.5%

stability

Not exceeding ± 0.5% FS/30minute

Power supply

AC220±22V, (50±1Hz

Size (mm), Weight (kg)

250×95×600.4

Same series turbidity meter:

Model Name

Main technical parameters

Performance Characteristics

Description and Product Configuration

Price (CNY)

WZS-188Type turbidity meter

Measuring range 0.000-20.00NTU

20.01-200.0NTU

200.1-2000)NTU(2001-4000 )NTU

Indication error: not greater than±6 %

repetitiveness≤0.5%

Tungsten lamp light source, compliant withUSEPA 180.1The requirements;

Support zero and multiple7Point calibration; Support calibration restore function to restore factory calibration data;

Automatic range switching;

Support average measurement function, compensating for reading fluctuations caused by random floating of suspended solids in the sample through average calculation;

comply withGLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to1000Group;

haveUSBandRS-232Communication interface,Support connectionPCAnd the printer.

WZS-188Standard Package

WZS-188Host, turbidity bottle400NTUStandard turbidity solution

9800

WZS-186Type turbidity meter

Measurement range:(020.00),

(20.0200.0), (2002000NTU
Indication error≤±6%(FS)
repetitiveness≤±0.5%(FS)

●LEDLight source, using880nmWavelength, long lifespan, meets the requirementsISO7027Standard;

Using scattering-Transmission light measurement principle, automatic chromaticity compensation;

Full range measurement, automatic range switching, automatic zero adjustment;

Automatic calibration:7Point calibration, meeting zero point calibration and any other requirements7Point calibration;

● Avg-ReadFunction: ThroughaverageShortcut keys can quickly calculate the average of multiple consecutive measurements, compensating for reading fluctuations caused by random floating of suspended solids in the sample;

comply withGLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to2000Group;

standardUSBCommunication interface,

Equipped with power-off protection and automatic shutdown function

WZS-186Standard Package

WZS-186Host, turbidity bottle400NTUStandard turbidity solution

8600

WZS-185AType turbidity meter

Measurement range:(020.00NTU

(20.0200.0NTU, (2001000NTU
Indication error≤±6%(FS)
repetitiveness≤±0.5%(FS)

●LEDLight source, using880nmWavelength, long lifespan, meets the requirementsISO7027Standard;

Using scattering-Transmission light measurement principle, automatic chromaticity compensation;

Full range measurement, automatic range switching, automatic zero adjustment;

Automatic calibration:6Point calibration, meeting zero point calibration and any other requirements6Point calibration;

● Avg-ReadFunction: ThroughaverageShortcut keys can quickly calculate the average of multiple consecutive measurements, compensating for reading fluctuations caused by random floating of suspended solids in the sample;

comply withGLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to2000Group;

standardUSBCommunication interface,

Equipped with power-off protection and automatic shutdown function

WZS-185AStandard Package

WZS-185AHost, turbidity bottle400NTUStandard turbidity solution

6800

WZS-180AType turbidity meter

Measuring range020.00)NTU

(20.0200.0)NTU
Indication error≤±8%(FS)
repetitiveness≤±1%(FS)

●LEDLight source, using880nmWavelength, long lifespan, meets the requirementsISO7027Standard;

Using scattering-Transmission light measurement principle, automatic chromaticity compensation;

Full range measurement, automatic range switching, automatic zero adjustment;

Automatic calibration:4Point calibration, meeting zero point calibration and any other requirements4Point calibration;

Equipped with automatic shutdown function

WZS-180AStandard Package

WZS-180AHost, turbidity bottle400NTUStandard turbidity solution

4600

WGZ-2000turbidimeter

Measurement range:(0.0050.0NTU

(50.1200)NTU

(2012000)NTU
Error: in0-200NTUNot greater than±8 % in201-2000NTUNot greater than±6 %

Light source: tungsten halogen lamp

Operation: Touch screen

scattering-Transmitting light measurement, automatic chromaticity compensation

Automatic range switching

WGZ-2000Standard Package

WGZ-2000Host, turbidity bottle400NTUStandard turbidity solution

7800

Model Name

Main technical parameters

Performance Characteristics

Description and Product Configuration

Price (CNY)

WZB-175Portable turbidity meter

Measuring range

020.00NTU, (20.0200.0NTU, (2001000NTU

Indication error≤±6%;

repetitiveness±0.5%;

●LEDLight source, using850 nmWavelength, satisfyingISO 7027Standard;

Using scattering-Transmission light measurement principle, multi-directional reception of scattered light signals, ratio calibration, automatic chromaticity compensation;

Automatic range switching and zero adjustment;

Support zero and multiple6Point calibration;

Support average measurement function;

Support storage2000The group test data meets the requirementsGLPstandard;

supportUSBCommunication, supports connectionPCConduct data collection;

Support battery powered andUSBPower supply, supports power management, and supports automatic shutdown;

●IP65Protection level, good waterproof and dustproof performance;

Provide turbidity calibration solution as a matching solution.

WZB-175Standard Package

WZB-175Host, turbidity bottle400NTUCalibration solution

5200

WZB-172Portable turbidity meter

Measuring range

020.00NTU, (20.0500.0NTU

Indication error≤±6%;

repetitiveness±0.5%;

●LEDLight source, using850 nmWavelength, satisfyingISO 7027Standard;

Using scattering-Transmission light measurement principle, multi-directional reception of scattered light signals, ratio calibration, automatic chromaticity compensation;

Automatic range switching and zero adjustment;

Support zero and multiple5Point calibration;

Support average measurement function;

Support storage500The group test data meets the requirementsGLPstandard;

supportUSBCommunication, supports connectionPCConduct data collection;

Support battery powered andUSBPower supply, supports power management, and supports automatic shutdown;

●IP65Protection level, good waterproof and dustproof performance;

Provide turbidity calibration solution as a matching solution.

WZB-172Standard Package

WZB-172Host, turbidity bottle400NTUCalibration solution

4200

WZB-171Portable turbidity meter

Measuring range

020.00NTU, (0.00200.0NTU

Indication error≤±6%;

repetitiveness±0.5%;

●LEDLight source, using850 nmWavelength, satisfyingISO 7027Standard;

Automatic range switching and zero adjustment;

Support zero and multiple3Point calibration;

Support average measurement function;

Support storage200The group test data meets the requirementsGLPstandard;

supportUSBCommunication, supports connectionPCConduct data collection;

Support battery powered andUSBPower supply, supports automatic shutdown;

●IP65Protection level, good waterproof and dustproof performance;

Provide turbidity calibration solution as a matching solution.

WZB-171Standard Package

WZB-171Host, turbidity bottle400NTUCalibration solution

3600

WZB-170Portable turbidity meter

Measurement range:(020.00NTU, (20.0200.0NTU

Indication error≤±8%;

repetitiveness±1.0%;

Light source, using850 nmWavelength, satisfyingISO 7027Standard;

Automatic range switching and zero adjustment;

Support zero and multiple3Point calibration;

Support battery powered andUSBPower supply, supports automatic shutdown;

●IP65Protection level, good waterproof and dustproof performance;

WZB-170Standard Package

WZB-170Host, turbidity bottle

2600