Brand: Shanghai Leici (Yidian)
Name: Turbidity meter, Turbidity meter
Model: WZS-185A
【 Main Features 】
lLEDLight source, satisfyingISO7027Standard;
lUsing scattering-Transmission light measurement principle, automatic chromaticity compensation;
lAutomatic range switching;
lSupport zero and multiple 6Point calibration;
lSupport average measurement function, compensating for reading fluctuations caused by random floating of suspended solids in the sample through average calculation;
lCompliant with GLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to2000Group;
lEquipped with standard USBCommunication interface, supporting andPCconnect;
lIt has power-off protection function.
|
model Technical Specifications |
WZS-185A |
measurement range |
0~20.00)NTU, (20.0~200.0)NTU, (200~1000)NTU |
indication error |
Not exceeding ± 6% |
repetitiveness |
Not exceeding 0.5% |
stability |
Not exceeding ± 0.5% FS/30minute |
Power supply |
AC(220±22)V, (50±1)Hz |
Size (mm), Weight (kg) |
250×95×60,0.4 |
Same series turbidity meter:
Model Name |
Main technical parameters |
Performance Characteristics |
Description and Product Configuration |
Price (CNY) |
WZS-188Type turbidity meter |
Measuring range (0.000-20.00)NTU, (20.01-200.0)NTU, (200.1-2000)NTU,(2001-4000 )NTU; Indication error: not greater than±6 %; repetitiveness≤0.5%; |
●Tungsten lamp light source, compliant withUSEPA 180.1The requirements; ●Support zero and multiple7Point calibration; Support calibration restore function to restore factory calibration data; ●Automatic range switching; ●Support average measurement function, compensating for reading fluctuations caused by random floating of suspended solids in the sample through average calculation; ●comply withGLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to1000Group; ●haveUSBandRS-232Communication interface,●Support connectionPCAnd the printer. |
【WZS-188Standard Package WZS-188Host, turbidity bottle400NTUStandard turbidity solution |
9800 |
WZS-186Type turbidity meter |
Measurement range:(0~20.00), (20.0~200.0), (200~2000)NTU; |
●LEDLight source, using880nmWavelength, long lifespan, meets the requirementsISO7027Standard; ●Using scattering-Transmission light measurement principle, automatic chromaticity compensation; ●Full range measurement, automatic range switching, automatic zero adjustment; ●Automatic calibration:7Point calibration, meeting zero point calibration and any other requirements7Point calibration; ● Avg-ReadFunction: Through“average”Shortcut keys can quickly calculate the average of multiple consecutive measurements, compensating for reading fluctuations caused by random floating of suspended solids in the sample; ●comply withGLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to2000Group; ●standardUSBCommunication interface, ●Equipped with power-off protection and automatic shutdown function |
【WZS-186Standard Package WZS-186Host, turbidity bottle400NTUStandard turbidity solution |
8600 |
WZS-185AType turbidity meter |
Measurement range:(0~20.00)NTU, (20.0~200.0)NTU, (200~1000)NTU; |
●LEDLight source, using880nmWavelength, long lifespan, meets the requirementsISO7027Standard; ●Using scattering-Transmission light measurement principle, automatic chromaticity compensation; ●Full range measurement, automatic range switching, automatic zero adjustment; ●Automatic calibration:6Point calibration, meeting zero point calibration and any other requirements6Point calibration; ● Avg-ReadFunction: Through“average”Shortcut keys can quickly calculate the average of multiple consecutive measurements, compensating for reading fluctuations caused by random floating of suspended solids in the sample; ●comply withGLPStandardized, supporting data retrieval and deletion, with a data storage capacity of up to2000Group; ●standardUSBCommunication interface, ●Equipped with power-off protection and automatic shutdown function |
【WZS-185AStandard Package WZS-185AHost, turbidity bottle400NTUStandard turbidity solution |
6800 |
WZS-180AType turbidity meter |
Measuring range0~20.00)NTU, (20.0~200.0)NTU; |
●LEDLight source, using880nmWavelength, long lifespan, meets the requirementsISO7027Standard; ●Using scattering-Transmission light measurement principle, automatic chromaticity compensation; ●Full range measurement, automatic range switching, automatic zero adjustment; ●Automatic calibration:4Point calibration, meeting zero point calibration and any other requirements4Point calibration; ●Equipped with automatic shutdown function |
【WZS-180AStandard Package WZS-180AHost, turbidity bottle400NTUStandard turbidity solution |
4600 |
WGZ-2000turbidimeter |
Measurement range:(0.00~50.0)NTU; (50.1~200)NTU; (201~2000)NTU; |
●Light source: tungsten halogen lamp ●Operation: Touch screen ●scattering-Transmitting light measurement, automatic chromaticity compensation ●Automatic range switching |
【WGZ-2000Standard Package WGZ-2000Host, turbidity bottle400NTUStandard turbidity solution |
7800 |
Model Name |
Main technical parameters |
Performance Characteristics |
Description and Product Configuration |
Price (CNY) |
WZB-175Portable turbidity meter |
Measuring range (0~20.00)NTU, (20.0~200.0)NTU, (200~1000)NTU; Indication error≤±6%; repetitiveness±0.5%; |
●LEDLight source, using850 nmWavelength, satisfyingISO 7027Standard; ●Using scattering-Transmission light measurement principle, multi-directional reception of scattered light signals, ratio calibration, automatic chromaticity compensation; ●Automatic range switching and zero adjustment; ●Support zero and multiple6Point calibration; ●Support average measurement function; ●Support storage2000The group test data meets the requirementsGLPstandard; ●supportUSBCommunication, supports connectionPCConduct data collection; ●Support battery powered andUSBPower supply, supports power management, and supports automatic shutdown; ●IP65Protection level, good waterproof and dustproof performance; ●Provide turbidity calibration solution as a matching solution. |
【WZB-175Standard Package WZB-175Host, turbidity bottle400NTUCalibration solution |
5200 |
WZB-172Portable turbidity meter |
Measuring range (0~20.00)NTU, (20.0~500.0)NTU; Indication error≤±6%; repetitiveness±0.5%; |
●LEDLight source, using850 nmWavelength, satisfyingISO 7027Standard; ●Using scattering-Transmission light measurement principle, multi-directional reception of scattered light signals, ratio calibration, automatic chromaticity compensation; ●Automatic range switching and zero adjustment; ●Support zero and multiple5Point calibration; ●Support average measurement function; ●Support storage500The group test data meets the requirementsGLPstandard; ●supportUSBCommunication, supports connectionPCConduct data collection; ●Support battery powered andUSBPower supply, supports power management, and supports automatic shutdown; ●IP65Protection level, good waterproof and dustproof performance; ●Provide turbidity calibration solution as a matching solution. |
【WZB-172Standard Package WZB-172Host, turbidity bottle400NTUCalibration solution |
4200 |
WZB-171Portable turbidity meter |
Measuring range (0~20.00)NTU, (0.00~200.0)NTU; Indication error≤±6%; repetitiveness±0.5%; |
●LEDLight source, using850 nmWavelength, satisfyingISO 7027Standard; ●Automatic range switching and zero adjustment; ●Support zero and multiple3Point calibration; ●Support average measurement function; ●Support storage200The group test data meets the requirementsGLPstandard; ●supportUSBCommunication, supports connectionPCConduct data collection; ●Support battery powered andUSBPower supply, supports automatic shutdown; ●IP65Protection level, good waterproof and dustproof performance; ●Provide turbidity calibration solution as a matching solution. |
【WZB-171Standard Package WZB-171Host, turbidity bottle400NTUCalibration solution |
3600 |
WZB-170Portable turbidity meter |
Measurement range:(0~20.00)NTU, (20.0~200.0)NTU; Indication error≤±8%; repetitiveness±1.0%; |
●Light source, using850 nmWavelength, satisfyingISO 7027Standard; ●Automatic range switching and zero adjustment; ●Support zero and multiple3Point calibration; ●Support battery powered andUSBPower supply, supports automatic shutdown; ●IP65Protection level, good waterproof and dustproof performance; |
【WZB-170Standard Package WZB-170Host, turbidity bottle |
2600 |