Manufacturer of flow current meter

NegotiableUpdate on 01/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

SCD flow current analyzer is used for continuous online measurement of charges on small suspended particles and colloids in liquids. The measurement results of charges are converted into A.C signals or flow current (SC) through electronic signal processing. The flow current (SC) value is proportional to the charge density, and the charged state depends on the excess positive and negative charges in the water after flocculation. By detecting changes in the flow current (SC) value, the characteristics of water (such as color and turbidity) can be quickly reflected, allowing operators to adjust the dosage of flocculants accordingly.

Product Details

water quality requirements

Conductivity:< 3000μS/cm

PH: 4-11pH (control pH<7 after adding flocculant, measured by scd)The effect is quite good

TSS:< 1000mg/L

advantage

● Automatic control of flocculant addition

● Save flocculant costs

Ensure that the effluent quality meets the standard

Low operating and maintenance costs

Technical Specifications

Measurement parameters: Flowing current/SCD,pH

Measurement range:-1000~1000SC,0-14pH

Accuracy ±0.1%,±0.01pH

Repeatability: ±0.1%

Response time:1s

Operating temperature: 0-50℃

Liquid connection material:PTFE、POM、SS316

Shell:ABS/PC

Power supply:220VAC,50/60Hz

Analog output:2-channel 4-20mA (measured values and PID),The most daLoad 500 Ω

Relay output:2-channel high/low relays, capable of setting alarm values and hysteresis values

Automatic cleaning: Cleaning interval:0-9999min, Cleaning time: 0-9999 seconds

Digital Communication:RS485 Modbus RTU

Data storage: Real time data recording, supportingUSB drive export (Excel format)

Sampling requirements: The time from adding flocculant to the sensor is about3-5min

Protection level:IP65

Size: controller200×190×90mm,

Sensor:250×350×150mm

Weight: Controller: Approximately1Kg, Sensor: Approximately 5Kg