Magnetic oxygen analysis detector has a long lifespan

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The FT-CY10 magnetic oxygen analysis detector is designed based on the paramagnetic principle and uses an imported magnetic oxygen sensor (Shifumei). It has the characteristics of high detection accuracy, long service life, good stability, and fast response. It can be made into various forms such as portable, online, explosion-proof, etc. according to the actual working conditions of customers.

Product Details

FT-CY10typemagnetOxygen analysis detectorBased on the paramagnetic principle, the imported magnetic oxygen sensor (Shifumei) is used, which has the characteristics of high detection accuracy, long service life, good stability, and fast responseIt can be made into various forms such as portable, online, explosion-proof, etc. according to the actual working conditions of customers.

applicationField:

Petroleum pipeline engineering, cement plantProtective gases for high-temperature sintering furnaces such as air separation for nitrogen production, storage, chemical processes, magnetic materials, protective gases for the electronics industry, and protective gases for the glass and building materials industriesHyperbaric oxygen chamberThe oxygen content is onlinedetectionanalysis.

Instrument features:

At the bottomNo reference gas required

At the bottomUsing imported sensors with long lifespanGood stabilityHigh precision, fast response and other characteristics

At the bottomlarge screendot matrixformulaLCDdisplayOptional display unit%、mg/ m3

At the bottomAutomatic measurement datareal-timerecordThe recorded data can be displayed in the form of curves or lists

At the bottomTwo arbitrarily adjustable control points,passiverelay output, standard4-20mA current output

At the bottomstandardRS232 or RS485 communication port, capable of communicating with computers

At the bottomVarious forms of use, customizable online and explosion-proof

Following standards:

At the bottomGB/T 18403.3-2014 Gas analyzers - Performance indicators - Part 3: Paramagnetic oxygen analyzers

At the bottomJJG 662-2005 Verification Regulations for Paramagnetic Oxygen Analyzer

Technical Specifications:

At the bottomMeasurement range: customizable according to customer requirements

At the bottomessence degree≤±1%F. S

At the bottomheavy again Sex:≤±1%F. S

At the bottomstability≤±1%F. S

At the bottomResponse time:T90 ≤ 30 seconds.

At the bottomWorking environment: Temperature: -25℃~+55℃humidity≤90%RH(No condensation).

At the bottomSample gas pressure:0.05 MPa ≤ inlet pressure ≤ 0.1 MPa. (The outlet must be at atmospheric pressure)

At the bottomSample gas flow rate:400±10mL/ min.

At the bottomPower supply220VAC±10%,50Hz±5%.

At the bottomOverall dimensions:485Mm (width) ×176mm (height) ×360Mm (depth).

At the bottomHole size:452Mm (width) × 174Mm (height).

At the bottomheavyQuantity: Approximately5kg

Principle Description

Magnetic Oxygen Analysis DetectorBy utilizing the principle of paramagnetism of oxygen molecules, strong interactions are generated in a magnetic field, leading the measured gas to the built-in magnetic field. Oxygen molecules move in accordance with the magnetic field and generate thrust on the suspended dumbbell ball. The oxygen content in the measured gas is obtained by measuring the offset of the dumbbell ball.

图片1.png