Laser cutting machine for Chater Dewar bottles

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DC230LP Chater Dewar mass spectrometer is equipped with an MVE liquid nitrogen tank, which mainly consists of a tank body, monitoring device, safety device, pressure balance circuit, valves, and other accessories. Its main control valve group and joints are installed on the top of the tank body for easy operation and can be connected to various standard sized hoses.

Product Details

DC230LP Chater Dewar Mass Spectrometer with MVE Liquid Nitrogen Tank

Chart'sDura-CylinderThe Dewar flask liquid nitrogen tank is mainly designed for efficient liquid nitrogen supply and efficient gas use. The liquid storage and preservation time of the Dewar flask is longer, the static volatilization rate is lower, and the effective utilization rate is higher.Many liquid nitrogen supply scenarios use Chart's230LPModel: Liquid Nitrogen Supply Liquid Nitrogen TankChart liquid nitrogen tankIts exceptional insulation structure results in minimal or no product loss over a period of time. For example, in terms of efficient gas usage, one180MPThe capacity of a Dewar flask is equivalent to18The pressure is2400psigHigh pressure gas cylinder


one Product advantages:


1liquid nitrogencanThe Dewar flask is mainly composed of a tank body, monitoring device, safety device, pressure balancing circuit, valves, and other accessories. Its main control valve group and joints are installed at the top of the tank body for easy operation and can beconnectVarious standard sizes of hoses.


2liquid nitrogen tankThe inner and outer tanks of the main structure of the tank are mainly made of austenitic stainless steel. The internal high vacuum insulation material is used for insulation, and after vacuum treatment, the vacuum layer is insulated from the thermal insulation,Vacuum layer thickness25mmDurable and long-lasting.


3Combination pressure control regulation, ultra-low vaporization loss.LCCMCombination pressure regulating valve, which has been calibrated; Specially designed for Chart; Integrating turbocharging and economic return; Readable, mechanically adjustable structure. The Chart pressure regulating valve can directly read the pressure of the boosting circuit under the regulating cap.


4The Chater Dewar bottle liquid nitrogen tank is equipped with two convenient carts for you to easily move and transport the tank body.

5The reusable vacuum port of Chart * is easy to maintain.

6The standard Charter liquid level gauge is convenient for understanding the liquid nitrogen level inside the tank, facilitating the filling and use of liquid nitrogen. And it can360 °Rotate.DC230LP Chater Dewar Mass Spectrometer with MVE Liquid Nitrogen Tank


two Technical Specifications

Product Model/Model

DC230LP

DC230MP

DC230HP

capacity/Capacity

Geometric volume/Gross (liters/L)

240

240

240

Net volume/Net(L/L)

230

230

230

Overall dimensions/Size

Outer Shell Diameter (cm/cm)

60.6

60.6

60.6

Base size/Square Base size (cm/cm)

63

63

63

Height/Height (cm/cm)

160

160

160

Technical Specifications/Technical Parameter

Safety valve set pressure (megapascal/PSI)

Relief Valve Setting(MPa/PSI)

0.15/22

1.58/230

2.41/350

Explosive disc set pressure (megapascal/PSI)

SecondaryRelief Valve Setting(MPa/PSI)

1.38/200

2.76/400

4.13/600

Pressure regulating valve set pressure (MPa/PSI)

Kinglator setting pressure(MPa/PSI)

0.12/18

0.86/125

2.07/300

Empty Weight/Empty Weight (kg/kg)

145

168

185

Filling weight/Full Filling Weight(kilogram/kg)*

Liquid oxygen/CO2

258

229

223

Liquid nitrogen/LN2

182

163

156

Liquid argon/LAr

318

275

270

Liquid carbon dioxide/LCO2

/

/

239

Gas volume under standard conditions/Standard Gas Volume(Nm3)

Oxygen/O2

/

164

156

Nitrogen/N2

/

132

124

Argon/Ar

/

160

151

Carbon dioxide/CO2

/

/

121

Daily evaporation rate(liquid nitrogen)/NER(LN2)

1.5%

1.8%

1.8%

airflow rate/Gas Flow Rate ( Nm3/hr)

Oxygen, nitrogen, argon (O2, N2, Ar)

/

10.5

10.5

Carbon dioxide (CO2)

/

2.9

2.9

* Filling weight under the set pressure of the safety valve/Fill weight is based on relief valve setting pressure



three Function Configuration

1Gas phase valveCan directly output gas for use

2Liquid phase valveFilling or outputting liquids

3Voltage regulator/superchargerControl (Connect)/Disconnect the pressure control regulator

4Exhaust valveRelease the pressure inside the tank

5Safety valveOverpressure relief

6Pressure gauge, safety valve, bursting disc

7Boosting valve - open the tank for boosting pressure

9Liquid level gauge&protective coverLiquid volume in welded insulated gas cylinders


four Instructions for using the Chater Dewar flask


AUsing gas
1 Connect the gas pipeline to the joint of the gas usage valve, and use two wrenches to tighten the joint to prevent loosening and air leakage.

2 Open the pressure increasing valve of the Dewar flask and place it in automatic pressure regulation mode.
3 Open the gas usage valve to start supplying gas to the gas consuming equipment.
4 If not in use for a long time, close the gas usage valve and pressure boosting valve to avoid waste.
5 After use, close all valves on the Dewar flask to prevent air and its impurities from entering the flask and causing contamination.
6 Dismantle the pipeline connected to the gas usage valve. When loosening the pipeline, it is necessary to ensure that the gas inside the pipeline has been emptied, and use two wrenches to prevent loosening of the joint, which may cause air leakage.



BLiquid usage
1 Connect the liquid pipeline to the joint of the liquid valve, and use two wrenches to tighten the joint to prevent loosening and air leakage.
2 Open the pressure regulator valve of the Dewar flask and place it in automatic pressure regulation mode. However, for users who use low-pressure tanks or liquid nitrogen for freezing, the pressure regulator valve can be opened and closed according to the speed of liquid nitrogen extraction to choose the appropriate pressure, but generally the pressure should not exceed0.2Mpa.

3 Slowly start the liquid valve and start taking the liquid.

4 If not in use, close the liquid valve and booster valve to avoid waste.

5 After use, close all valves on the Dewar flask to prevent air and its impurities from entering the flask and causing contamination.

6 Dismantle the pipeline connected to the liquid valve. When loosening the pipeline, it is necessary to ensure that the gas inside the pipeline has been emptied, and use two wrenches to prevent loosening the joint, which may cause air leakage at the joint.



fiveKey safety points for storage and use
1The storage and use area must maintain sufficient ventilation to prevent nitrogen and argon gas leakage or discharge, which may cause hypoxia and suffocation; Prevent oxygen leakage or discharge, which can lead to the formation of oxygen enrichment and easily cause surrounding substances to catch fire.
-Storage and use areas must be kept away from sources of fire, heat, and corrosive substances.

2When using liquids, it is necessary to wear leather gloves or insulated gloves to operate low-temperature components and keep them dry to prevent frostbite of the skin on the hands.

3When taking liquid nitrogen from a Dewar flask for freezing, it is necessary to wear a face mask to prevent liquid nitrogen from flying and freezing the face, skin, and eyes.

4Components such as pipelines, joints, and sealing materials used in oxygen must not contain grease and must be compatible with oxygen.

5If you have any questions, please contact our company