Deminzhe 17 series EX intrinsic safety explosion-proof
Intrinsically safe explosion-proof magnetostrictive displacement sensor

| Absopos Technology Magnetostriction Technology |
|
The operating principle of magnetostriction (Absopos) is achieved by analyzing the feedback signal of mutual induction between two magnetic fields. The first magnetic field operates on the sensor housing using a permanent magnet. The second magnetic field is generated by a pulse generator. When two magnetic fields induce each other, an absolute position signal will be fed back with ultrasonic velocity. The precision circuit system will analyze the waveform of ultrasonic waves and output a precise and high-resolution position signal, allowing the machine to enter the production state in real time. |
|
Advantages of intrinsically safe explosion-proof magnetostrictive displacement sensor FOR EXTREMELY ACCURATE,LOW-NOISE,AND WEAR-FREE ABSOLUTE POSITION FEEDBACK |
|
lIntrinsic safety explosion-proofThe magnetostrictive displacement sensor adopts non-contact ultrasonic measurement technology. Can provide the best linear and absolute position measurement.
|
| Standard specifications | ||
| Measurements | Linear displacement | |
| Power supply | +12VDC | |
| input protection | Polarity protection up to -30Vdc, overvoltage protection up to 36Vdc | |
| Power consumption | 50-140mA (depending on the range) | |
| Dielectric Strength | 500Vdc (DC ground to machine ground) | |
| output | 0-10VDC, 10-0VDC dual output, minimum load resistance 5k Ω | |
| resolution | Infinite (depending on controller A/D and power ripple) | |
| repeatability | <± 0.005% of full range | |
| Nonlinearity | <± 0.01% of full scale (maximum ± 90 μ m) | |
| operation temperature | -40 to 85 ℃ | |
| Protection level | IP67 (straight out cable) | |
| Oscillation index | 10-2000Hz/IEC standard 68-2-6 | |
| Impact Index | 100g (single impact)/IEC standard 68-2-27 (durability) | |
| update time | 0.5ms within 1200mm/1.0ms within 2400mm/2.0ms within 4800mm | |
| compressive strength | When installed in the hydraulic cylinder, it is 600 bar | |
| Fixed method | Thread M18 * 1.5 | |
| Housing material | Aluminum, anodized/outer protective tube, flange made of 304 stainless steel precision casting |
Intrinsic safety explosion-proof magnetostrictive displacement sensor (magnet installation guide)

Intrinsic safety explosion-proof magnetostrictive displacement sensor (hydraulic cylinder installation legend)

Intrinsic safety explosion-proof magnetostrictive displacement sensor (shell size)