Welcome Customer !

Membership

Help

Shanghai Naiai Experimental Instrument Co., Ltd
Custom manufacturer

Main Products:

plast-mach>Products
Product Categories

Shanghai Naiai Experimental Instrument Co., Ltd

  • E-mail

    naaiyiqi@foxmail.com

  • Phone

    13817064805

  • Address

    Room J7389, Building 1, No. 2222 Huancheng Road, Juyuan New District, Jiading District, Shanghai

Contact Now

Intelligent liquid-liquid extractor supplier

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The intelligent liquid-liquid extraction instrument is mainly used to replace hand cranked extraction in liquid-liquid extraction and optimize the liquid-liquid extraction process. This instrument replaces manual shaking and adopts a semi enclosed air flow internal circulation oscillation. Its principle is to use air pressure to fully combine the water sample and extractant and collide vigorously
Product Details

Shanghai Naiai Experimental Instrument Equipment [Naiai Instrument Manufacturer] Website National Delivery Manufacturer First Hand Goods!

Experimental instruments are not electronic products, and their efficiency and after-sales service are very important. We compare price with quality, efficiency with price, and after-sales service with efficiency.

The equipment and instruments belong to precision equipment. Customer order records are free of charge and have a one-year quality guarantee. Any problems can be resolved by providing spare parts for maintenance and upkeep

Shanghai Naiai Instrument is an instrument enterprise focused on experimental instrument design, research and development, production, and sales. Currently, we sell and produce integrated distillation instruments, traditional Chinese medicine sulfur dioxide distillation instruments, COD digestion instruments, high chlorine COD digestion instruments, sulfide acidification blowing instruments, fully automatic liquid-liquid extraction instruments, volatile oil determination instruments, and more.

The intelligent liquid-liquid extraction instrument is mainly used to replace hand cranked extraction in liquid-liquid extraction and optimize the liquid-liquid extraction process. This instrument replaces manual shaking and adopts a semi enclosed air flow internal circulation oscillation. Its principle is to use air pressure to fully combine water samples and extractants and collide vigorously to achieve the purpose of extraction, reducing unnecessary labor for experimental personnel, protecting the health of operators, improving extraction efficiency, and making analysis results more stable and reliable. Suitable for situations requiring liquid-liquid extraction such as petroleum in water quality monitoring, and can also be used for automatic liquid-liquid extraction of volatile phenols and anionic surfactants in water.

Main features


1. The instrument body adopts a frame integrated design, which is stable and reliable. The main body is made of branded cold-rolled plate with electrostatic powder coating, which is more wear-resistant and corrosion-resistant;
2. From air to contacts, relay protectors to button switches, etc., use Chint/Delixi or equivalent electrical brands to ensure instrument quality and service life;
3Adopting a PLC control system with stable and powerful performance, the 7-inch touch screen can achieve full process control such as automatic extraction, automatic exhaust, automatic cleaning, and automatic waste discharge;
4. It can extract 1 to 4 samples at once, and the sample bottles are four sets of three port separating funnel extraction bottles with polytetrafluoroethylene valves, with standard 500ml or 1000ml capacity;
5. Each extraction bottle has an independent glass air duct inserted into the bottom of the extraction bottle (which can be replaced with a PTFE blowing plug and PTFE air duct according to customer needs);
6. Adopting the semi enclosed airflow oscillation principle and continuously inflating with an internal air pump to achieve oscillatory extraction, the extraction intensity can be adjusted from weak to strong;
7. During the reaction process, exhaust gas is generated, which is automatically and uniformly discharged and treated without the need for manual venting, while avoiding the risk of bursting of fully enclosed extraction bottles;
8. Each extraction bottle is equipped with a specially designed glass spray cleaning plug, which uses a constant pressure scattering wide-angle cleaning technology to fully cover the inner wall of the separation funnel. The dual channel automatic suction of detergent or pure water enables automatic rinsing of the extraction bottle;
9. The cleaned waste liquid is discharged into the waste water tank inside the host through an independent push-pull waste liquid collection tank, which is made of POM material resistant to organic solvent corrosion;
10. The waste liquid tank is equipped with a liquid level device, which automatically starts the waste liquid discharge program after reaching the preset water level. After filtering some toxic and harmful substances through activated carbon, the waste is uniformly discharged;
11. The system comes with an instruction manual and a QR code for the service center. Scanning the code with your phone will automatically view the electronic instruction manual and connect to the service center with just one click.


Applicable standard


HJ 637-2018 Water quality - Determination of petroleum, animal and vegetable oils - Infrared spectrophotometric method
HJ 970-2018 Water quality - Determination of petroleum content - UV spectrophotometric method
HJ 503-2009 Determination of volatile phenols in water quality -4-amino spectrophotometric method
HJ 478-2009 Determination of Polycyclic Aromatic Hydrocarbons in Water Quality - Liquid Liquid Extraction and Solid Phase Extraction High Performance Liquid Chromatography Method
HJ 591-2010 Determination of Water Quality Gas Chromatography Method
HJ 648-2013 Determination of Nitrobenzene Compounds in Water Quality Liquid Liquid Extraction/Solid Phase Extraction Gas Chromatography Method
HJ 676-2013 Determination of Phenolic Compounds in Water Quality Liquid Liquid Extraction Gas Chromatography Method
HJ 744-2015 Determination of Phenolic Compounds in Water Quality Gas Chromatography Mass Spectrometry Method
HJ 753-2015 Water Quality - Determination of Chlorothalonil and Pesticides - Gas Chromatography Mass Spectrometry Method
HJ 699-2014 Water quality - Determination of organochlorine pesticides and chlorobenzene compounds - Gas chromatography-mass spectrometry method

GB/T 5750.4-2006 Standard Test Methods for Drinking Water - Sensory Characteristics and Physical Indicators
GB/T 5750.5-2006 Standard Test Method for Drinking Water Inorganic Non metallic Index
GB/T 5750.6-2006 Standard Test Method for Drinking Water Metal Index
GB/T 5750.7-2006 Standard Test Method for Drinking Water - Comprehensive Index of Organic Compounds
GB/T 5750.8-2006 Standard Test Method for Drinking Water Organic Matter Index
GB/T 5750.9-2006 Standard Test Method for Drinking Water Pesticide Index
GB 8538-2016 National Food Safety Standard Inspection Method for Drinking Natural Mineral Water
GB/T 7494-1987 Water quality - Determination of anionic surfactants - spectrophotometric method

GB 5009.26-2016 National Food Safety Standard Determination of N-nitrosamine compounds in food
GB 5009.82-2016 National Food Safety Standard Determination of A, D, and E in Food
GB/T 5009.20-2003 Determination of Organophosphorus Pesticide Residues in Foods
GB/T 5009.102-2003 Determination of pesticide residues in plant-based foods
HJ 1189-2021 Determination of 28 Organophosphorus Pesticides in Water Quality by Gas Chromatography Mass Spectrometry
GB/T 5009.218-2008 Determination of multiple pesticide residues in fruits and vegetables
GB/T 20771-2008 Determination of Residues of 486 Pesticides and Related Chemicals in Honey by Liquid Chromatography Tandem Mass Spectrometry

SN/T 1739-2006 Method for detecting residues of multiple organophosphorus pesticides in grain and oilseeds for import and export - Gas chromatography tandem mass spectrometry
SN/T 2158-2008 Method for detecting residual ticks in imported and exported food poisoning


Product Parameters


Product Name Intelligent liquid-liquid extractor
Product Model NAI-CQY4S NAI-CQY6S
Control method PLC control+7-inch touch screen
Quantity of extracted samples Standard configuration includes 4 500ml or 1000ml extraction bottles Standard configuration includes 6 500ml or 1000ml extraction bottles
Reagent addition method manually add
Extraction method Semi enclosed air circulation oscillation, independently controlled automatic extraction
Extraction strength Adjustable, from weak to strong
Extraction time and method Adjustable between 0~999 seconds, 0~99 times
Post extraction processing Static layering, manually adding liquid
Cleaning time and method Dual channel automatic suction of detergent or pure water, automatic flushing
waste gas treatment Automatic air release, no manual release required during operation. The exhaust gas is collected and processed centrally after being filtered and adsorbed by a filtering storage tank
waste liquid treatment Automatic discharge of waste liquid, which is filtered and adsorbed through activated carbon storage tanks for centralized treatment
Extraction bottle sample rack Supporting: One extraction bottle sample rack