Automatic dielectric loss tester for dielectric constantPerformance characteristics: ◎ Fully automatic one click operation can automatically scan the smoothest range stage. ◎ The microcomputer processor responds quickly and calculates the frequency band in the shortest possible time
◎ Fixture digital display ◎ 4.3-inch TFT LCD display ◎ Chinese and English optional operation interface
◎Test frequency of 2MHz, resolution of 10mHz
◎ Balance testing function ◎ Transformer parameter testing function
Test speed: 13ms/time
◎ Automatic Level Adjustment (ALC) function for voltage or current
◎ V and I test signal level monitoring function
Internal built-in DC bias source
◎ Can be connected to an external high current DC bias source
◎ 10 point list scanning test function
◎ 30 Ω, 50 Ω, 100 Ω optional internal resistance
Built in comparator with 10 levels of sorting and counting functions
Internal file storage and external USB file saving
Measurement data can be directly saved to a USB drive
◎ RS232C, USB, LAN, Handler, GPIB, DCI interfaces
The high-frequency impedance analyzer has a capacitance value Cp resolution of 0.00001pF and a 6-digit D value display, ensuring the accuracy and repeatability of ε and D values.
The measurement range of dielectric constant can reach 1-105
Main technical indicators:
Performance of ε and D:
Testing of ε and D changes in solid insulation materials at frequencies ranging from 20Hz to 2MHz. Measurement range of ε and D: ε: 1-105, D: 0.1-0.00005,
Measurement accuracy of ε and D (10kHz): ε: ± 2%, D: ± 5% ± 0.0001.
Test parameters: C, L, R, Z, Y, X, B, G, D, Q, θ, DCR
Test frequency: 20 Hz~2MHz, 10mHz step
Test signal voltage: f ≤ 1MHz 10mV~5V, ± (10%+10mV)
平 : f>1MHz 10mV~1V,±(20%+10mV)
Output impedance: 10 Ω, 30 Ω, 50 Ω, 100 Ω
Basic accuracy; 0.1%
Display range:
L 0.0001 uH ~ 9.9999kH
C :0.0001 pF ~ 9.9999F
R,X,Z,DCR :0.0001 Ω ~ 99.999 MΩ
Y, B, G 0.0001 nS ~ 99.999 S
D :0.0001 ~ 9.9999
Q :0.0001 ~ 99999
θ :-179.99°~ 179.99°
Measurement speed; Fast: 200 times/s (f>30kHz), 100 times/s (f>1kHz)
Medium speed: 25 times/s, slow speed: 5 times/s
Calibration function: open/short circuit point frequency, sweep frequency reset, load calibration
Equivalent methods: series connection, parallel connection
Range mode: automatic, hold
Display mode: direct reading, Δ, Δ%
Trigger mode: internal, manual, external, bus
Internal DC bias: Voltage mode -5V~+5V, ± (10%+10mV), 1mV step
Source setting: Current mode (internal resistance of 50 Ω) -100mA~+100mA, ± (10%+0.2mA), 20uA step
Comparator function: 10 level sorting and counting function
monitor; 320 × 240 dot matrix graphic LCD display
Memory: capable of storing 20 sets of instrument settings
USB DEVICE( USBTMC and USBCDC support) USB HOST(FAT16 and FAT32 support)
Interface: LAN (LXI class C support) RS232C HANDLERGPIB (optional)
Working frequency range: 20Hz~2MHz digital synthesis,
Accuracy: ± 0.02%
Capacitance measurement range: 0.00001pF to 9.99999F six digit digital display
Basic error of capacitance measurement: ± 0.05%
Loss factor D value range: 0.00001 to 9.99999 six digit digital display
Dielectric constant testing device (including protective electrode): The precision dielectric constant testing device provides testing electrodes and can accurately measure samples with diameters ranging from 10 to 56mm and thicknesses less than 10mm. <>
It can be set up as three methods for different samples: contact electrode method, thin film electrode method, and non-contact method, to adapt to testing soft materials, uneven surfaces, and thin film samples.
Differential head resolution: 10 μ m
Voltage resistance: ± 42Vp (AC+DC)
Cable length setting: 1m
Usage frequency: 30MHz
High frequency dielectric sample (optional): In the current high-frequency dielectric material verification system, the measurement standard provided by the verification department for the high-frequency dielectric loss measuring instrument is the high-frequency standard dielectric sample. This sample is made of artificial sapphire, quartz glass, alumina ceramic, polytetrafluoroethylene, epoxy board and other materials with a diameter of 50mm and a thickness of 1-2mm for testing. Users can order as needed to ensure the repeatability and accuracy of the testing device.
Automatic dielectric loss tester for dielectric constantTest data printing. After the test is completed, click the "Print" button with a touch pen or finger on the test result interface to print out the test data. test After printing or storing data, click the "Exit" button with a touch screen pen or finger, and the instrument will return to the initial startup interface.