How much does the TCU temperature control system cost

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview of Heating and Refrigeration TCU Temperature Control System Product: The entire liquid circulation is sealed with an expansion container. The expansion container and the liquid circulation are insulated and do not participate in the liquid circulation. They are only mechanically connected, regardless of whether the temperature of the liquid circulation is high or low. The medium in the expansion container is below 60 degrees Celsius.

Product Details

Heating and coolingTCU temperature control systemProduct Overview:

The entire liquid circulation is sealed with an expansion container. The expansion container and the liquid circulation are insulated and do not participate in the liquid circulation. They are only mechanically connected, regardless of whether the temperature of the liquid circulation is high or low. The medium in the expansion container is below 60 degrees Celsius.
The entire liquid circulation is a closed system, with no absorption of water vapor at low temperatures and no generation of oil mist at high temperatures. Thermal oil can operate at a wide range of temperatures; There are no mechanical or electronic valves used in the entire circulation system.

Product Features:
◆ Wide working temperature range, with heating and cooling functions, maximum temperature range: -50 ℃~180 ℃.
A controller with two LED displays that can simultaneously display temperature set values, actual values, and over temperature alarm values.
◆ Efficient, fast, and easy to fill.
◆ Ensure rapid cooling under high temperature conditions; It can achieve continuous temperature control from 180 degrees to -50 degrees.
◆ Circular management with fully enclosed treatment, no oil mist or water absorption, ensuring the safety of the experiment and the lifespan of the heat transfer fluid.
The refrigeration unit is equipped with a Gulen compressor and circulating pump from the United States, which have stable performance and reliable quality.
◆ Has self diagnostic function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device and other safety protection functions.
Control the temperature of the thermal conductive medium, and use the same thermal conductive medium throughout the entire cooling process.
High head design, suitable for long-distance transportation of thermal conductive media.

Heating and coolingTCU temperature control systemTechnical Specifications:

model

GTZL-2525

GTZL-2535

GTZL-2555

GTZL-2570

GTZL-25100

GTZL-25150

Temperature control range

-25℃~200℃

control mode

Feedforward PID, PLC control

controller

5.7-inch color touch screen, temperature curve display and recording

compressor

American Grain Wheel

refrigerant

404A

electrical

Schneider

evaporator

High pressure plate heat exchanger in Taiwan, China, China

Temperature controlled object

Material temperature control and jacket temperature control can be freely selected.

Temperature difference control

The temperature difference between the jacket of the reaction vessel and the material temperature can be controlled and set.

programmable

100 sequences can be developed, and each program can be programmed with 100 steps

communication

MODBUS RTU protocol RS 485 interface

temperature feedback

Thermal medium temperature feedback PT100 Material temperature feedback PT100

temperature control accuracy

±1℃

heating power

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

cooling capacity

200℃

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

100℃

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

20℃

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

-5℃

2kW

3 kW

4.5kW

6.6kW

8kW

12kW

-20℃

1kW

1.8kW

2.8kW

3.8kW

4.6kW

7kW

Circulating pump flow

Quantity and pressure

Max20min

2BAR

Max35L/min

2BAR

Max35min

2BAR

Max50L/min

2BAR

Max50L/min

2BAR

Max110L/min

2.5BAR

safety protection

Having self diagnostic function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection device and other safety protection functions.

closed system

The entire system is a fully enclosed system, which does not produce oil mist at high temperatures and does not absorb moisture from the air at low temperatures. The system does not increase pressure due to high temperatures during operation, and automatically replenishes the heat transfer medium at low temperatures.

interface dimensions

DN15

DN20

DN-25

Overall dimensions

400*600*1050

500*680*1350

550*680*1450

550*680*1650

620*680*1550

750*750*1750

weight

115kg

165kg

185kg

230kg

280kg

300kg

power supply

AC220V 50HZ

4kW (max)

AC380V 50HZ

6kW (max)

AC380V 50HZ

8kW (max)

AC380V 50HZ

11kW (max)

AC380V 50HZ

14kW (max)

AC380V 50HZ

21kW (max)