WDZ-KYJY33, WDZN-YJY23, WDZN-KYJYP2-23, WDZ-KYJYP2, WDZN-KYJYP2-23 halogen-free low smoke flame-retardant fire-resistant armored cables
Halogen free low smoke fire-resistant armored cables are suitable for power systems or control and monitoring circuits in subways, high-rise buildings, shopping malls, theaters, power stations, chemical factories, city squares, and other public utilities with AC rated voltage of 600/1000V and below. The commonly used name for halogen-free low smoke cables isLow smoke halogen-free cable.
Execution standards: Adopting enterprise standards and referring to GB9330-88 and GB/T12706-2002
Usage characteristics:
1The cable is allowed to work at a temperature of 90 ℃ for a long time
2. The temperature for cable laying shall not be lower than 0 ℃
3. Recommended bending radius
Halogen free low smoke flame-retardant control cable: For unarmored cables, the outer diameter of the cable should not be less than 6 times, and for cables with armor or copper tape shielding structures, the outer diameter of the cable should not be less than 12 times.
Halogen free low smoke flame-retardant power cable: The bending radius of a single core cable shall not be less than 20 times the outer diameter of the cable, and the bending radius of a multi-core cable shall not be less than 15 times the outer diameter of the cable.
Halogen-free low smoke fire-resistant armored cableCable model and name:
model |
name |
Halogen-free low smoke flame-retardant power cable | |
WDZ-YJY |
Copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant power cable (can also be made of aluminum core WDZ-YJLY) |
WDZ-YJY23 |
Copper core cross-linked polyethylene insulated steel tape armored halogen-free low smoke flame-retardant power cable (can also be made of aluminum core WDZ-YJLY23) |
WDZ-YJY33 |
Copper core cross-linked polyethylene insulated steel wire armored halogen-free low smoke flame-retardant power cable (can also be made of aluminum core WDZ-YJLY33) |
WDZN-YJY |
Copper core cross-linked polyethylene insulated halogen-free, low smoke, flame-retardant and fire-resistant power cable |
WDZN-YJY23 |
Copper core cross-linked polyethylene insulated steel tape armored halogen-free low smoke flame-retardant and fire-resistant power cable |
WDZN-YJY33 |
Copper core cross-linked polyethylene insulated steel wire armored halogen-free low smoke flame-retardant and fire-resistant power cable |
Model name of halogen-free low smoke flame-retardant control cable:
WDZ-KYJY |
Copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant control cable |
WDZ-KYJYP |
Copper core cross-linked polyethylene insulated copper wire shielded halogen-free low smoke flame-retardant control cable |
WDZ-KYJYP2 |
Copper core cross-linked polyethylene insulated copper tape shielded halogen-free low smoke flame-retardant control cable |
WDZ-KYJYP2-23 |
Copper core cross-linked polyethylene insulated copper tape shielded steel tape armored halogen-free low smoke flame-retardant control cable |
WDZ-KYJY33 |
Copper core cross-linked polyethylene insulated fine steel wire armored halogen-free low smoke flame-retardant control cable |
WDZN-KYJY |
Copper core cross-linked polyethylene insulated halogen-free low smoke flame-retardant and fire-resistant control cable |
WDZN-KYJYP2 |
Copper core cross-linked polyethylene insulated copper tape shielded halogen-free low smoke flame-retardant control cable |
WDZN-KYJYP2-23 |
Copper core cross-linked polyethylene insulated copper tape shielded steel tape armored halogen-free low smoke flame-retardant control cable |
Explanation of Nouns and Terms:
model |
rated voltage |
0.5 |
0.75 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
WZD-KYJY KYJYP |
600/1000V |
2-61core |
2-37core |
2-14core |
|||||
WZD-KYJYP2 KYJY33 |
4-61core |
||||||||
WDZN-KYJY |
2-61core |
||||||||
WDZN-KYJYP2 KYJYP2-23 |
4-61core |
||||||||
WDZ-YJY YJLY |
Single core: 2.5mm2~500mm2 |
||||||||
WDZ-YJY23 YJLY23 | |||||||||
WDZ-YJY33 YJLY33 | |||||||||
WDZN-YJY YJY23 | |||||||||
WDZN-YJY33 | |||||||||
Technical Indicators:
1The direct current resistance of the conductor complies with the provisions of GB/T3956
2. The insulation resistance constant at 90 degrees is not less than 3.67M Ω Km, The volume resistivity shall not be less than 1012 Ω Cm
3. Cable 3.5KV AC voltage test, insulation does not break down for 5 minutes
4Performance indicators of halogen-free low smoke flame-retardant cables:
Test Project |
unit |
Performance Requirements |
Test Method |
Smoke density test |
% |
60 |
GB/T17651-1998 |
Corrosion test |
μS/mm |
4.3 |
GB/T17650.2-1998(idtIEC60754) |
Content of hydrogen halide gas |
mg/g |
Less than or equal to 5 |
GB/T17650.1-1998(idtIEC60754) |
Bundle test |
min |
A B C |
GB/T18380.3-2001(Replace for GB12666.5-90) |
Product Specifications
Nominal cross-sectional area mm2 |
0.5 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
16 |
25 |
core count |
2-81 |
2-81 |
2-81 |
2-50 |
2-37 |
2-20 |
2-19 |
2-14 |
2-10 |