This type of condensate pump is widely used for the circulation and pressurization of cold and hot water in high-pressure operating systems, parallel water supply of multiple pumps in high-rise buildings, fire protection, boiler feedwater and cooling water systems, and the transportation of various flushing liquids.
| model | Flow rate m3/h | Head m | Suction distance m | Motor power kw |
| 25GDL2-12×3 | 2 | 36 | 7.5 | 1.1 |
| 25GDL2-12×4 | 48 | 1.1 | ||
| 25GDL2-12×5 | 60 | 1.5 | ||
| 25GDL2-12×6 | 72 | 1.5 | ||
| 25GDL2-12×7 | 84 | 2.2 | ||
| 25GDL2-12×8 | 96 | 2.2 | ||
| 25GDL2-12×9 | 108 | 2.2 | ||
| 25GDL2-12×10 | 120 | 3 | ||
| 25GDL2-12×11 | 132 | 3 | ||
| 25GDL2-12×12 | 144 | 3 | ||
| 25GDL4-11×3 | 4 | 33 | 1.1 | |
| 25GDL4-11×4 | 44 | 1.5 | ||
| 25GDL4-11×5 | 55 | 2.2 | ||
| 25GDL4-11×6 | 66 | 2.2 | ||
| 25GDL4-11×7 | 77 | 3 | ||
| 25GDL4-11×8 | 88 | 3 | ||
| 25GDL4-11×9 | 99 | 3 | ||
| 25GDL4-11×10 | 110 | 4 | ||
| 25GDL4-11×11 | 121 | 4 | ||
| 25GDL4-11×12 | 132 | 4 | ||
| 25GDL4-11×13 | 143 | 4 | ||
| 40GDL6-12×3 | 6 | 36 | 1.5 | |
| 40GDL6-12×4 | 48 | 2.2 | ||
| 40GDL6-12×5 | 60 | 2.2 | ||
| 40GDL6-12×6 | 72 | 3 | ||
| 40GDL6-12×7 | 84 | 3 | ||
| 40GDL6-12×8 | 96 | 4 | ||
| 40GDL6-12×9 | 108 | 4 | ||
| 40GDL6-12×10 | 120 | 4 | ||
| 40GDL6-12×11 | 132 | 5.5 | ||
| 40GDL6-12×12 | 144 | 5.5 | ||
| 50GDL12-15×2 | 12 | 30 | 7 | 2.2 |
| 50GDL12-15×3 | 45 | 3 | ||
| 50GDL12-15×4 | 60 | 4 | ||
| 50GDL12-15×5 | 75 | 5.5 | ||
| 50GDL12-15×6 | 90 | 5.5 | ||
| 50GDL12-15×7 | 105 | 7.5 | ||
| 50GDL12-15×8 | 120 | 75 | ||
| 50GDL12-15×9 | 135 | 11 | ||
| 50GDL12-15×10 | 150 | 11 | ||
| 50GDL18-15×3 | 18 | 45 | 4 | |
| 50GDL18-15×4 | 60 | 5.5 | ||
| 50GDL18-15×5 | 75 | 7.5 | ||
| 50GDL18-15×6 | 90 | 7.5 | ||
| 50GDL18-15×7 | 105 | 11 | ||
| 50GDL18-15×8 | 120 | 11 | ||
| 50GDL18-15×9 | 135 | 15 | ||
| 50GDL18-15×10 | 150 | 15 | ||
| 65GDL24-12×2 | 24 | 24 | 6 | 3 |
| 65GDL24-12×3 | 36 | 4 | ||
| 65GDL24-12×4 | 48 | 5.5 | ||
| 65GDL24-12×5 | 60 | 7.5 | ||
| 65GDL24-12×6 | 72 | 7.5 | ||
| 6S5GDL24-12×7 | 84 | 11 | ||
| 65GDL24-12×8 | 96 | 11 | ||
| 65GDL24-12×9 | 108 | 15 | ||
| 65GDL24-12×10 | 120 | 15 | ||
| 80GDL36-12×2 | 36 | 24 | 5.5 | 4 |
| 80GDL36-12×3 | 36 | 5.5 | ||
| 80GDL36-12×4 | 48 | 7.5 | ||
| 80GDL36-12×5 | 60 | 11 | ||
| 80GDL36-12×6 | 72 | 11 | ||
| 80GDL36-12×7 | 84 | 15 | ||
| 80GDL36-12×8 | 96 | 15 | ||
| 80GDL36-12×9 | 108 | 18.5 | ||
| 80GDL36-12×10 | 120 | 18.5 | ||
| 80GDL54-14×2 | 54 | 28 | 5 | 7.5 |
| 80GDL54-14×3 | 42 | 11 | ||
| 80GDL54-14×4 | 56 | 15 | ||
| 80GDL54-14×5 | 70 | 18.5 | ||
| 80GDL54-14×6 | 84 | 18.5 | ||
| 80GDL54-14×7 | 98 | 22 | ||
| 100GDL72-14×2 | 72 | 28 | 4.5 | 11 |
| 100GDL72-14×3 | 42 | >15 | ||
| 100GDL72-14×4 | 56 | 18.5 | ||
| 100GDL72-14×5 | 70 | 22 | ||
| 100GDL72-14×6 | 84 | 3>0 | ||
| 100GDL72-14×7 | 98 | 30 |




| Fault phenomenon | Possible causes | exclusion method |
| 1. The water pump is not producing water | The inlet valve is not open, the inlet and outlet pipelines are blocked, and the impeller flow channel is blocked The motor is running in the wrong direction and has a slow speed due to phase loss Leakage of suction pipe The pump is not filled with liquid and there is air inside the pump chamber Insufficient imported water supply, high suction, and bottom valve leakage Excessive pipeline resistance and improper pump selection |
Check and remove blockages Adjust the motor direction and tighten the motor wiring Tighten all sealing surfaces and eliminate air Open the pump cover or open the exhaust valve to exhaust all the air Shutdown inspection and adjustment Reduce pipeline bends and reselect pumps |
| 2. Insufficient water pump flow | First, check for reason 1 Pipeline, pump flow channel or impeller blockage, scale deposition Low voltage Impeller wear |
First, press 1 to exclude Remove the obstruction and readjust the valve opening voltage stabilization Replace the impeller |
| 3. Excessive power | Exceeding the rated flow usage High suction distance Pump bearing wear |
Adjust the flow rate and turn down the outlet valve reduce replace the bearing |
| 4. Noise vibration | Unstable pipeline support Liquid mixed with gas Generate cavitation Bearing damage Motor overload operation |
Stable pipeline Increase suction pressure and exhaust 降低真空度 replace the bearing Adjust according to 5 |
| 5. Motor overheating | Excessive traffic and overloaded operation 局部摩擦 Motor bearings damaged Insufficient voltage |
Close the outlet valve Check and exclude replace the bearing voltage stabilization |
| 6. Water pump leakage | Mechanical seal wear The pump body has sand holes or cracks Uneven sealing surface Loosening of installation bolts |
replace Welding repair or replacement trim fasten |