The Fusible Link Valve combines the advantages of ball valves and butterfly valves, using the principle of spherical or butterfly structure, composed of a fuse device, receiving temperature sensing of heat, and controlling the cutting, connection, or switching of fluids in the process pipeline. It has the characteristics of simple structure, sensitive response, and reliable action. The fuse valve actuator melts at an ambient temperature of ≥ 80 ℃ and quickly closes or opens, playing a role in safety and fire prevention, thereby preventing the possibility of accidents escalating again.
Fusible Link Valve product features:
1. It can automatically cut off in case of fire
2. The melting temperature can be selected from 165 ° F (74 ℃) to 360 ° F (182 ℃)
3. Materials include carbon steel, stainless steel, and fluorine lining4. The valve body has ball valves and butterfly valves5. Connection method: ball valve/thread, welding, flange. Butterfly valve/clamp, flange
6. Application media: ammonia, gas, liquefied gas, methanol, oil, combustible gas/liquid
7. Using 304 stainless steel components ensures cleanliness during oil transportation and improves corrosion resistance
Emergency state of fuse emergency valve, i.e. handling in case of fire or damage:
If the valve is damaged or closed due to fire or vibration, the valve body and accessories should be checked for integrity in a timely manner. If there is any damage, it should be replaced immediately. In any case, before putting the valve back into use, it is necessary to check whether the valve body and accessories are intact.
Precautions for testing and repairing emergency circuit breakers:
When conducting testing or maintenance, the switch device (valve) in front of the fuse valve must be turned off.
Only act in emergency situations. In order to enable it to operate correctly in emergency situations, it should be manually opened and closed at least three times a year to assist in the deposition of prepaid debris or other situations that may cause the valve to malfunction.
FUSHIBLE LINK BALL VALVE Fusible Connection Ball Valve
FUSHIBLE LINK BUTTERFLY VALVE Fusible Connection Butterfly Valve
Fire Safe Ball Valve with Automatic Thermal Shutoff Device
Thermal Shut Off Valves
Fusible Link Safety Shutoff Valves
FUSHIBLE LINK VALVE fuse connection valve
FIRE SAFE VALVES fire safety valves
FUSHIBLE VALVES Fusible Valve
Fusible Valve
FIRE SAFE BUTTERFLY VALVES Fireproof Butterfly Valve
Fire Valves Fire Dampers