Electroplating chemical industry chiller
Electroplating chiller/electroplating dedicated chiller/electroplating industrial chiller/electroplating chiller prices
In the electroplating industry, chillers help stabilize metal ions, allowing them to quickly attach to the electroplated parts. This not only increases density and smoothness, but also reduces the number of electroplating cycles and improves production efficiency. In addition, chillers help to quickly recover various chemicals, reduce waste, and save money.
※Electroplating chiller/electroplating dedicated chiller/electroplating industrial chiller/electroplating chiller prices
Refrigeration principle
The water cooled by the chiller is pumped to the heat exchanger (separated in the middle, with one side of water and one side of tank solution), while the tank solution in the electroplating tank is pumped to the heat exchanger through an acid and alkali resistant water pump. The two liquids are cooled through the transfer process in the heat exchanger, and the cooled tank solution flows back to the electroplating tank through the pipeline. At the same time, the hot water after heat exchange also flows back to the water tank through the pipeline, completing a cycle of work.

Electroplating chiller/electroplating dedicated chiller/electroplating industrial chiller/electroplating chiller prices
Product features:
◆The refrigeration system has a long service life:The chiller can be placed at a certain distance from the plating tank (in an area free of acid and alkali corrosion), which not only maintains the cleanliness and beauty of the chiller's appearance, but also protects the machine itself, avoiding the corrosion of electrical components by high-temperature acid and alkali chemicals, thereby extending the service life of the chiller;
◆Easy installation:By using acid and alkali resistant plate heat exchangers, the acid and alkali zones near the plating tank can be placed, which enables close range transportation of the acid and alkali tank and reduces the corrosiveness of the acid and alkali solution to external objects during transportation. Moreover, this exchanger has a small volume and can effectively save space for customers;
◆Cost savings:Users can freely increase the number of electroplating tanks without the need to purchase additional chillers. They only need to add plate heat exchangers, effectively saving costs for users;
◆Low maintenance costs:Plate heat exchangers are detachable and easy to maintain. The chiller will not cause harm to its own components even in high-temperature acidic and alkaline environments for a long time. Even if the plate heat exchanger malfunctions during long-term use, simply replacing the heat exchanger fins can ensure the normal and stable operation of the machine;
◆Accurate temperature control:Each electroplating tank and its corresponding heat exchanger form their own independent temperature control system to meet the temperature requirements of different products;
◆Strong adaptability:Plates made of different materials (stainless steel, titanium, alloy plates) can adapt to various special acidic and alkaline environments.
|
1.Electroplating chiller/electroplating dedicated chiller/electroplating industrial chiller/electroplating chiller pricesTechnical Parameter Table (1) Technical parameters table of Water-cooled Industrial Chiller(1)
|
|
parameter
Parameter
|
model Model
|
LC-
03W
|
LC-
05W
|
LC-
08W
|
LC-
10W
|
LC-
15W
|
LC-
20W
|
LC-
30W
|
LC-
40W
|
LC-
50W
|
|
|
KW 50HZ/60HZ
|
9.59
11.22
|
15.91
18.62
|
24.85
29.08
|
31.83
37.24
|
50.14
58.66
|
67.14
78.56
|
99.19
116.05
|
129.06
151.00
|
153.91
180.07
|
|
|
kczl/h 50HZ/60HZ
|
8251
9654
|
13690
16018
|
21375
25009
|
27370
32023
|
43120
50451
|
57748
67565
|
85303
99805
|
110984
129851
|
132359
154860
|
|
total input power
|
KW
|
2.8
|
4.3
|
6.8
|
8.4
|
13.1
|
17.3
|
25.6
|
33.1
|
42.5
|
|
power supply Power Supply
|
3N~380V/415V 50HZ/60HZ
|
|
refrigerant Refrigerant
|
Fill quantity
(kg)
|
1.7
|
2.8
|
2.2×2
|
2.8×2
|
4.2×2
|
5×2
|
7.5×2
|
10×2
|
12.5×2
|
|
compressor Compressor
|
Power Motor
(kw)
|
2.25
|
3.75
|
3×2
|
3.75×2
|
5.5×2
|
7.5×2
|
11.3×2
|
15×2
|
18.8×2
|
|
cooling water Cooling Water
|
Water flow
(m3/h)
|
2.06
2.1
|
3.42
4.00
|
5.34
6.25
|
6.85
8.01
|
10.78
12.61
|
14.44
16.90
|
21.32
24.94
|
27.74
32.46
|
33.09
38.72
|
|
|
Water resistance P.D
(Kpa)
|
28
|
34
|
38
|
34
|
28
|
38
|
36
|
35
|
42
|
|
chilled water Freeze Water
|
Water flow
(m3/h)
|
1.65
1.93
|
2.74
3.20
|
4.27
5.00
|
5.47
6.40
|
8.62
10.09
|
11.55
13.52
|
17.06
19.96
|
22.19
25.97
|
26.48
30.98
|
|
|
Water tank
(m3)
|
0.038
|
0.065
|
0.11
|
0.188
|
0.285
|
0.285
|
0.405
|
0.61
|
0.61
|
|
water pump Pump
|
Power Motor
(KW)
|
0.55
|
0.55
|
0.75
|
1.5
|
1.5
|
2.2
|
3.75
|
3.75
|
3.75
|
|
|
Lift Raise
(Kpa)
|
200
|
200
|
200
|
205
|
205
|
220
|
240
|
240
|
240
|
|
External dimensions Dimension
|
Long Length
(mm)
|
860
|
860
|
960
|
1360
|
1460
|
1460
|
1680
|
2080
|
2080
|
|
|
Width
(mm)
|
550
|
550
|
600
|
600
|
800
|
800
|
950
|
1000
|
1000
|
|
|
High Height
(mm)
|
930
|
1250
|
1440
|
1440
|
1610
|
1610
|
1810
|
1860
|
1860
|
|
Weight
|
(kg)
|
120
|
150
|
210
|
290
|
400
|
440
|
690
|
850
|
1000
|
Previous: High gloss mold temperature machine | Rapid cooling and heating mold temperature machine