The single wire and cable vertical combustion tester is suitable for research, production, and quality inspection departments of lighting equipment, low-voltage appliances, household appliances, machine tool appliances, motors, power tools, electronic instruments, electrical instruments, electrical connectors and auxiliary components, electrical and electronic products, and their component parts.
【singleRoot wire and cable vertical combustion testerProduct Description:
Single wire and cable vertical combustion testerSuitable for research, production, and quality inspection departments of lighting equipment, low-voltage appliances, household appliances, machine tool appliances, motors, power tools, electronic instruments, electrical instruments, electrical connectors and accessories, electrical and electronic products, and their component parts.
The testing instrument adoptsGB18380.12-2008The recommended product structure for the air mixture structure in China also meets the acceptance requirements of the quality inspection unit in terms of details. standardGB/T18380.1-2008TheGB/T18380.11-2008TheGB/T18380.12-2008TheGB/T18380.21-2008TheGB/T18380.22-2008TheGB/T19666-2005TheGB12972TheGB3003TheIEC60332TheMT818TheMT386TheISO5656
![单根电线电缆垂直燃烧试验仪]()
The vertical combustion test of a single wire and cable is conducted using a specified size of Bunsen burner and a specific gas source (propane). The flame is applied to the test sample in a vertical state at a fixed time according to a certain flame height and a first-class flame angle. The combustibility and ignition hazard of the test sample are evaluated based on the ignition, duration, and length of combustion.
Technical Specifications
Color screen controller: automatically records test time, automatically displays results, automatically counts time, automatically ignites, automatically returns to the original position, and can choose whether to turn off the gas.
Burner: Inner diameterΦ9.5mm±0.5mm
Experimental angle:45The horizontal beam of the specimen can be moved, and the position of the local lamp can be adjusted according to the thickness of the specimen
Flame height:20mm±2mmto190±1mmadjustable
Flame application time:0~999.9s±0.1sadjustable
Combustion gas:95%High purity propane gas (usually replaced by liquefied gas)
Ambient temperature23℃±10℃
Test piece length:600mm±25mm
Test piece diameter: should be greater than0.8mm
Combustion burner power:1kw
Voltage:220v/50Hz
Gas flow rate:0~1L/min
air flow1.5~15L/min
-
Overall dimensions:60cm×45cm×156cm
Standard recommends two flame calibration methods
Flame internal flame50~60mmThe outer flame170~190mm
-
10gCopper head from100Heat up to ℃700℃ time is45s±5s