Chemical gas chromatograph brand

NegotiableUpdate on 01/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Chemical product analysis gas chromatograph. The instrument adopts a large screen LCD display, which is intuitive and easy to operate. At the same time, the instrument comes with a digital interface, which enables real-time data signal acquisition, data processing, and detection results on the computer through a communication cable. Its beautiful and compact exterior design, equipped with modern computer control technology

Product Details

Instrument Introduction:Gas chromatograph is a new high-performance gas chromatograph designed through long-term research and experimentation on the basis of the original gas chromatograph. Using a large number of imported components for production and manufacturing, it has the advantages of good stability and reliability, stable gas flow path, simple structural design, beautiful appearance design, complete supporting facilities, and long service life.

Parameter characteristics:

15.7-inch full Chinese LCD screen (optional touch screen) with a user-friendly design interface and one click operation.

2Specially developed and designed split flow capillary injection system ensures the stability and accuracy of sample preparation; At the same time, it improves the service life of the chromatographic column and reduces the user's usage cost.

3Data power-off protection function, the operating data set by the instrument can be saved for a long time after power failure.

4Self diagnostic fault function, when the set parameters are different from the actual parametersThe instrument will stop running and report a fault on the display.

5Four types of detectors can be installed simultaneously, with independent circuit systems and signal output terminals.

6Large volume column box, capable of installing four chromatography columns simultaneously.

7The specially developed high-sensitivity detector and the integrated design of the electrostatic meter and ignition device have improved the sensitivity and resistance of the instrumentinterferencePower will not cause damage to the amplification circuit system due to ignition.

8The large Chinese screen displays instrument parameters intuitively, greatly facilitating user settings including temperature, pressure, flow rate, range, detector, bridge flow, and other parameters; Intuitive operation includes functions such as switching bridge current, opening and closing temperature control, opening and closing stroke lift, and various time events.

9The instrument computer is connected to the Internet and can be connected to the instrument through a remote computer to realize remote data collection and management. Improved the degree of freedom of the device and promoted its effective application in the laboratory.

10The main control circuit adopts functional dual microprocessors and large capacity memory, making data storage more reliable. The integrated design of the circuit board improves the anti-interference and reliability of the instrument.

11Using high-precision temperature control circuits, the temperature accuracy of the controlled objects in each heating zone reaches 0.1 degrees.

12The main box is equipped with an automatic rear door temperature control system, which improves the temperature control accuracy and cooling speed.

13Multi stage program heating, suitable for the analysis of complex samples with wide boiling points, can be increased to 21 stages.

14Unit based overall structural design, easy to install and maintain.

15Fully automatic adjustable automatic ignition, no need to press the ignition button to achieve true automatic ignition, and the ignition time can be set arbitrarily. Using alloy materials with an extremely long service life to ensure stability and longevity during use. In the past, old-fashioned ignition still required manual pressing of the keyboard to ignite, and the ignition time could not be set, which had a significant impact on the ignition interval and the lifespan of the ignition device, and also increased maintenance costs for users.

2、 Temperature control indicators:

Column box: Room temperature -450 ℃ accuracy ± 0.01 ℃ (measured at 200 ℃).
Sample injector: Room temperature -450 ℃ accuracy ± 0.01 ℃ (measured at 200 ℃).
Detector: Room temperature -450 ℃ accuracy ± 0.01 ℃ (measured at 200 ℃).
Up to six temperature control channels: suitable for multiple temperature control requirements such as installing conversion furnaces.
Column temperature box parameters:
Temperature control accuracy: Room temperature -420 ℃ accuracy ± 0.01 ℃.
Column temperature box volume: 280mm × 300mm × 280mm.
Program heating order: 9 orders. (21 levels can be added)
Program heating rate: 1 ℃ -50 ℃.
Constant temperature holding time for each stage: 0-300min (1min increments).
Automatic rear door design ensures rapid cooling.
A high-power, low-noise rotating fan ensures temperature uniformity.

IIIGas system:
The carrier gas flow rate adopts a dual stability design of first stabilizing and then stabilizing the flow.
Automatic display of work pressure, accuracy:<0.01
4、 Injection method:
Fill column head injection, fill column gasification injection.
Capillary diversion/non diversion injection: back pressure valve control technology, linear diversion.
Six way valve gas injection.
Online injection: 24-hour continuous injection without supervision.

5、 Other parameters:

Size: 590 * 480 * 500mm Weight: 55kg Input power supply: AC220V ± 10% 50HZ 10A 1800W

6、 High sensitivity detector parameters ensure the accuracy of data

FID-Hydrogen flame ionization detector:

Equipped with adjustable fully automatic ignition function as standard. Optional installation of EPC to achieve automatic cut-off of gas supply feedback function.

Detection limit: ≤ 3 × 10-12g/s

Drift: ≤ 0.1mv Noise: ≤ 0.01mv

TCD-Thermal conductivity detector:

Importrheniumtungsten filamentA semi diffusion detection tank can reduce pollution and extend the service life of the detection tank.

Detection limit:≥ 5000mv.ml/mg or 10000mv.ml/mg

Drift: ≤ 0.1mv Noise: ≤ 0.015mv

ECD-Electronic Capture Detector:

Universal detection pool that can share radioactive sources.

Detection limit:≤1×10-13g/ml(r-666)

Drift: ≤ 0.10mv Noise: ≤ 0.015mv

Technical features: Adjustable automatic ignition,Capillary nozzle responsetall

FPD-Flame photometric detector:

Newly designed nozzle system ensures high sensitivity.

Detection limit:Mp≤1×10-12g/s Ms≤5×10-11g/s

Drift: ≤ 0.10mv Noise: ≤ 0.015mv

NPD-Nitrogen and phosphorus detector:

Detection limit:Mn≤1×10-13g/s Mp≤1×10-14g/s

Drift: ≤ 0.10mv Noise: ≤ 0.015mv