Model significance

Product Introduction
CQB-F fluoroplastic magnetic pump is a new product developed by our unit in recent years. And advanced foreign technology is introduced, using polyvinylidene fluoride for manufacturing. This material is corrosion-resistant, and magnetic pumps produced with this material have a wide range of applications, strong corrosion resistance, high mechanical strength, no aging, and no toxin decomposition. It can be widely used in fields such as chemical, pharmaceutical, electroplating, petroleum, environmental protection, rare earth separation, smelting, and acid washing in automobile manufacturing.
The CQB-F fluoroplastic magnetic pump has a unique design that does not require mechanical shaft seals and does not leak. The liquid flow components are made of fluoroplastics, ceramics, fluororubber, and other materials. The pump body shell is fixed with metal materials, which can support the weight of the pipeline and facilitate use and maintenance.
Product Features
Adopting the principle of magnetic transmission, it can transport corrosive media without leakage.
Product Usage
CQB-F fluoroplastic magnetic pump is widely used in industries such as petroleum, chemical, metallurgical, pharmaceutical, electroplating, environmental protection, etc. It can transport strong acids, strong alkalis, strong oxidants, flammable, explosive, highly toxic and valuable liquids.
structural diagram
![]() |
serial number |
name |
material |
|||
1 |
pump body |
Cast iron Polyvinylidene fluoride |
||||
2 |
static ring |
99.5% alumina ceramic |
||||
3 |
power and environment monitoring system |
Fill polytetrafluoroethylene |
||||
4 |
impeller |
Polyvinylidene fluoride |
||||
5 |
gasket |
fluororubber |
||||
6 |
Isolation sleeve |
Polyvinylidene fluoride |
||||
7 |
Internal magnetic steel assembly |
Polyvinylidene fluoride |
||||
8 |
bushing |
silicon carbide ceramic |
||||
9 |
pump shaft |
silicon carbide ceramic |
||||
10 |
External magnetic steel assembly |
assembly |
||||
11 |
connection body |
cast iron |
||||
performance parameters
model |
caliber |
traffic |
head |
Necessary corrosion allowance (NPSH) |
Motor power |
speed |
efficiency |
voltage |
|
Imported products |
production |
(m3/h) |
(M) |
(M) |
(kw) |
(r/min) |
(%) |
380 |
|
CQB16-12-80F |
16 |
12 |
1.8 |
8 |
6.0 |
0.12 |
2900 |
220/380 |
|
CQB20-14-100F |
20 |
14 |
3 |
12 |
6.0 |
0.37 |
2900 |
220/380 |
|
CQB32-25-125F |
32 |
25 |
3.2 |
20 |
5.0 |
0.75 |
2900 |
35 |
380 |
CQB40-32-115F |
40 |
32 |
6.3 |
15 |
6.0 |
0.75 |
2900 |
45 |
380 |
CQB40-32-145F |
40 |
32 |
6.3 |
25 |
5.0 |
1.5 |
2900 |
42 |
380 |
CQB50-40-125F |
50 |
40 |
6.3 |
20 |
3.5 |
2.2 |
2900 |
50 |
380 |
CQB50-40-160F |
50 |
40 |
12.5 |
32 |
3.5 |
3 |
2900 |
46 |
380 |
CQB65-50-125F |
65 |
50 |
12.5 |
20 |
4.0 |
3 |
2900 |
58 |
380 |
CQB65-50-160F |
65 |
50 |
25 |
32 |
4.0 |
4 |
2900 |
56 |
380 |
CQB80-65-125F |
80 |
65 |
50 |
20 |
4.0 |
7.5 |
2900 |
66 |
380 |
CQB80-65-160F |
80 |
65 |
50 |
32 |
4.0 |
11 |
2900 |
64 |
380 |
CQB100-80-125F |
100 |
80 |
100 |
20 |
4.0 |
15 |
2900 |
72 |
380 |
CQB100-80-160F |
100 |
80 |
100 |
32 |
4.0 |
18.5 |
2900 |
70 |
380 |
Installation and usage instructions
1、 The CQB-F fluoroplastic magnetic pump should be installed horizontally and not vertically. The plastic pump should not bear the weight of the pipeline. For special vertical installation situations, the motor must face upwards.
2、 When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve
3、 Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal noise, and all fasteners should be tightened.
4、 Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump
5、 After the motor is started, slowly open the discharge valve and wait for the pump to enter normal operation before adjusting the discharge valve to the desired opening
6、 Before the pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed
Precautions
1、 Due to the fact that the cooling and lubrication of the CQB-F fluoroplastic magnetic pump bearings rely on the medium being transported, it is prohibited to operate them without load, and at the same time, it is necessary to avoid idle operation caused by power outage and restart during operation.
2、 When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve
3、 The environment during pump use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.
4、 The conveyed medium and its temperature should be within the allowable range of the pump material The operating temperature of engineering plastic pumps is less than 60 ℃, the operating temperature of metal pumps is less than 100 ℃, the conveying suction pressure is not greater than 0.2MPa, the working pressure is 1.6MPa, and the density is not greater than 1600kg/m3The particle size is not greater than 30 × 10-6M2/S liquid without hard particles and fibers.
5、 For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use to drain the accumulated liquid in the pump.
6、 After running the CQB-F fluoroplastic magnetic pump for 500 hours, the wear of the bearings and end face dynamic rings should be removed. If the gap between the bearings and the shaft sleeve is greater than 0.5-1mm, and the axial displacement of the impeller is 1.5-2mm, the bearings and axial dynamic rings should be replaced.
Faults and troubleshooting methods
Fault form |
root cause |
exclusion method |
||||||||||||
The pump is not producing water |
|
|
||||||||||||
Insufficient traffic |
|
|
||||||||||||
Head too low |
|
|
||||||||||||
The noise is too loud. |
|
|
||||||||||||
leakage |
|
|