E-mail
info@szetme.com
-
Phone
13728880902
-
Address
5th Floor, Honghai Building, Hongxing Community, Songgang Street, Bao'an District, Shenzhen
Shenzhen Yice Electric Co., Ltd
info@szetme.com
13728880902
5th Floor, Honghai Building, Hongxing Community, Songgang Street, Bao'an District, Shenzhen

Absopos Technology Maglev Technology |
|
The operating principle of magnetic levitation (Absopos) is achieved by analyzing the feedback signal of mutual induction between two magnetic fields. The first magnetic field operates on the sensor housing using a permanent magnet. The second magnetic field is generated by a pulse generator. When two magnetic fields induce each other, an absolute position signal will be fed back with ultrasonic velocity. The precision circuit system will analyze the waveform of ultrasonic waves and output a precise and high-resolution position signal, allowing the machine to enter the production state in real time. |
Advantages of magnetic levitation sensors |
|
l The magnetic levitation displacement sensor adopts non-contact ultrasonic measurement technology. Can provide the best linear and absolute position measurement.
|
Standard specifications |
||
Measurements |
Linear displacement |
|
Power supply |
+24Vdc (20.4 - 28.8Vdc) |
|
input protection |
Polarity protection up to -30Vdc, overvoltage protection up to 36Vdc |
|
Power consumption |
50-140mA (depending on the range) |
|
Dielectric Strength |
500Vdc (DC ground to machine ground) |
|
output |
0-10VDC, 10-0VDC dual output, minimum load resistance 5k Ω |
|
Distribution rate |
Infinite (depending on controller A/D and power ripple) |
|
Repetitive accuracy |
<± 0.005% of full range |
|
Nonlinearity |
<± 0.01% of full scale (maximum ± 90 μ m) |
|
operation temperature |
-40 to 85 ℃ |
|
Protection level |
IP65 (when plugged in correctly) |
|
Oscillation index |
10-2000Hz/IEC standard 68-2-6 |
|
Impact Index |
100g (single impact)/IEC standard 68-2-27 (durability) |
|
update time |
0.5ms within 1200mm/1.0ms within 2400mm/2.0ms within 4800mm |

Basic parameters
| Measurements | Linear displacement | |
| Power supply | +24Vdc (20.4 - 28.8Vdc) | |
| input protection | Polarity protection up to -30Vdc, overvoltage protection up to 36Vdc | |
| Power consumption | 50-140mA (depending on the range) | |
| Dielectric Strength | 500Vdc (DC ground to machine ground) | |
| output | There are two outputs: 0-10Vdc and 10-0VDC, with a minimum load resistance of 5K Ω and two outputs of 4-20mA and 20-4mA. The maximum load resistance is 700 Ω | |
| resolution | Infinite (depending on controller A/D and power ripple) | |
| Repetitive accuracy | <± 0.005% of full range | |
| linear accuracy | <± 0.01% of full scale (maximum ± 90 μ m) | |
| operation temperature | -40 to 85 ℃ | |
| Protection level | IP65 (when plugged in correctly) | |
| Oscillation index | 10-2000Hz/IEC standard 68-2-6 | |
| Impact Index | 100g (single impact)/IEC standard 68-2-27 (durability) | |
| update time | 0.5ms within 1200mm/1.0ms within 2400mm/2.0ms within 4800mm |