16 series magnetostrictive displacement sensor
characteristic
16 seriesmagnetostrictive displacement sensorIt is designed specifically for U-shaped lifting ring hydraulic cylinders or hydraulic cylinders that are limited by space. Its absolute position value is encoded into analog output or SSI binary code or Gray code and transmitted to the controller through serial RS422 standard. Combined with precise hydraulic cylinders and control valves, a high standard closed-loop control system is formed.

The 16 series magnetostrictive displacement sensor adopts non-contact technology in terms of product performancemagnetostrictive displacement sensorMeasurement technology can improve the accuracy, high reliability, stability, and direct and absolute output of displacement sensors. Non contact design is not only convenient and easy to install, but also eliminates all errors caused by work wear and tear, without the need for recalibration or regular maintenance. The electronic part is rated at IP65, providing the electronic module with optimal shock, dust, and moisture protection.
●Simulated voltage and current
●SSI synchronous serial number
| (Voltage/Current) Analog Output | ||||
| Order number | 160 |
161
|
||
| output | Voltage output (0-10V) |
Current output (0-20mA, 4-20mA)
|
||
| Measurements | Linear displacement |
|||
| Adjustable range |
When using dual magnets, the minimum distance between magnets is 76mm
|
|||
| resolution |
16 bit D/A, 0.0015% (minimum 1 μ m)
|
|||
| repeatability | Full scale < ± 0.001% (minimum ± 2.5 μ m) |
|||
| Nonlinearity | Full scale < ± 0.01% (minimum ± 40 μ m) |
|||
| update time | 0.5ms within 1200mm/1.0ms within 2400mm |
|||
2.0ms within 4800mm/5.0ms within 7600mm |
||||
SSI synchronous serial digital output |
||
| Order number |
162
|
|
| output |
SSI synchronous serial output
|
|
| Measurements | Linear displacement |
|
| data format |
Binary or Gray code, options provide parity check and error bits
|
|
| Length |
8-32 bits
|
|
| Data Speed | Line length:<3<50<100<200<400m Speed: 1000<400<300<200<100kBd |
|
| update time | Travel: 300750100020005000mm Frequency: 3.73.02.31.20.5kHz |
|
| resolution | Location: 1/2/5/10/20/50/100 μ m |
|
| All types have common parameters | ||||
| Power supply | +24Vdc(20.4 - 28.8Vdc) |
|||
| input protection | Polarity protection up to -30Vdc, overvoltage protection up to 36Vdc |
|||
| Power consumption | 100mA (depending on the measurement range) |
|||
| Dielectric Strength | 500Vdc (DC ground to machine ground) |
|||
| Joint selection | 6-pin D60 male connector |
|||
| operation temperature | -40 to 75 ℃, 90% temperature, no condensation |
|||
| Protection level | IP67 (when plugged in correctly) |
|||
| MACD Histogram | 15g/10-2000Hz/IEC standard 68-2-6 |
|||
| Impact Index | 100g (single impact)/IEC standard 68-2-27 (durability) |
|||
| EMC Testing | Radiation EN61000-6-3, anti-interference EN61000-6-2, EN61000-4-2/3/4/6 |
|||